Содержание 16048B

Страница 1: ... underutilized and idle equipment along with credit for buybacks and trade ins Custom engineering so your equipment works exactly as you specify Critical and expedited services Leasing Rentals Demos In stock Ready to ship TAR certified secure asset solutions Expert team I Trust guarantee I 100 satisfaction All trademarks brand names and brands appearing herein are the property of their respective ...

Страница 2: ...Agilent 16048B Test Leads Operating Note Third Edition Agilent Part No 16048 90012 May 2000 Printed in Japan Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Страница 3: ...8 90011 November 1998 Second Edition part number 16048 90012 May 2000 Third Edition part number 16048 90012 Safety Summary The following general safety precautions must be observed during all phases of operation service and repair of this instrument Failure to comply with these precautions or with specific WARNINGS elsewhere in this manual may impair the protection provided by the equipment In add...

Страница 4: ... when handling testing and adjusting this instrument Certification Agilent Technologies certifies that this product met its published specifications at the time of shipment from the factory Agilent Technologies further certifies that its calibration measurements are traceable to the United States National Institute of Standards and Technology to the extent allowed by the Institution s calibration ...

Страница 5: ...he product or improper site preparation or maintenance IMPORTANT No other warranty is expressed or implied Agilent Technologies specifically disclaims the implied warranties of merchantability and fitness for a particular purpose Exclusive Remedies The remedies provided herein are buyer s sole and exclusive remedies Agilent Technologies shall not be liable for any direct indirect special incidenta...

Страница 6: ...HANGES ERRATA CHANGES 1 CHANGE 1 contains the information needed to adapt the 16048B s manual Page 1 2 Specification Add the following information Maximum Voltage 40V peak max AC DC NOTE Manual change supplement are revised as often as necessary to keep manuals as current and accurate as possible Agilent Technologies recommends that you periodically request the latest edition of this supplement Fr...

Страница 7: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Страница 8: ...Hz C V Meter HP 4284A Precision LCR Meter HP 4285A Precision LCR Meter HP 4192A LF Impedance Analyzer HP 4194A Impedance Gain Phase Analyzer The HP 16048B has inherent stray capacitance residual inductance and residual resistance that a ect the accuracy of measured value The measurement errors caused by these residuals are minimized by using the instrument s error correction functions The measurem...

Страница 9: ...ail about the cable length correction and open short correction procedure refer to the instrument s operation manual Using the connector plate The connector plate is furnished with the HP 16048B Figure 1 2 shows an example to use the connector plate with the HP 16048B By connecting the HP 16048B to the connector plate the HP 16048B s outer shield conductors are connected together to construct the ...

Страница 10: ... Top 16 1400 0719 2 Tie Rap 21 2360 0113 1 Screw 22 3050 0010 1 Washer 23 16021 50021 1 Cable Cramp 24 16021 50022 1 Cable Cramp 30 1250 1164 4 Connector Body 16048 60030 1 Test Lead 1 thru 30 31 1250 0829 4 Connector RF 32 2360 0115 2 Screw 33 16033 10021 1 Plate 34 16032 10022 1 Plate 35 2190 0124 4 Washer 36 2950 0078 4 Nut 37 16033 60001 1 Connector Ass y 31 thru 36 Note The parts not shown in...

Страница 11: ...Figure 2 1 Replaceable Parts Identi cation 2 2 Maintenance Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Страница 12: ...opean Marketing Organization P O Box 999 1180 AZ Amstelveen The Netherlands tel 31 20 547 9999 Japan Agilent Technologies Japan Ltd Call Center 9 1 Takakura Cho Hachioji Shi Tokyo 192 8510 Japan tel 81 426 56 7832 fax 81 426 56 7840 Latin America Agilent Technologies Latin American Region Headquarters 5200 Blue Lagoon Drive Suite 950 Miami Florida 33126 U S A tel 305 267 4245 fax 305 267 4286 Aust...

Страница 13: ...quipment Have surplus equipment taking up shelf space We ll give it a new home Learn more Visit us at artisantg com for more info on price quotes drivers technical specifications manuals and documentation Artisan Scientific Corporation dba Artisan Technology Group is not an affiliate representative or authorized distributor for any manufacturer listed herein We re here to make your life easier How...

Отзывы: