6-12

11645A

Replaceable Parts

Introduction

Table 6-6   Items Not Included in the Verification Kit

Description

Qty

 Agilent

Part Number

ESD Protection Devices

Grounding wrist strap

1

9300-1367

5 ft grounding cord for wrist strap

1

9300-0980

2 x 4 ft conductive table mat and 15 ft ground wire

1

9300-0797

ESD heel strap (for conductive floors)

1

9300-1308

Connector Cleaning Supplies

Isopropyl alcohol

30 ml

8500-5344

Cleaning swabs

100

9301-1243

Содержание 11645A Series

Страница 1: ...nd W Waveguide Verification Kit This manual applies to the 11645A series calibration devices with serial number prefix 3014A Agilent Part Number 11645 90013 Printed in USA Print Date November 2004 Supersedes January 2002 Copyright Agilent Technologies Inc 1995 2002 2004 ...

Страница 2: ...OCUMENT THAT CONFLICT WITH THESE TERMS THE WARRANTY TERMS IN THE SEPARATE AGREEMENT WILL CONTROL DFARS Restricted Rights Notice If software is for use in the performance of a U S Government prime contract or subcontract Software is delivered and licensed as Commercial computer software as defined in DFAR 252 227 7014 June 1995 or as a commercial item as defined in FAR 2 101 a or as Restricted comp...

Страница 3: ...entation from the Web download the PDF file from the Agilent web site Go to http www agilent com Enter the document s part number located on the title page in the Quick Search box Click GO Click on the hyperlink for the document Click the printer icon located in the tool bar ...

Страница 4: ...iv ...

Страница 5: ... 3 What Causes Mating Surface Wear 3 3 Inspect the Mating Plane Surfaces 3 3 Cleaning the Mating Plane Surfaces 3 4 Connections 3 5 Connecting Waveguide Devices 3 5 How to Connect R band WR 28 3 5 How to Connect Q band WR 22 U band WR 19 V band WR 15 W band WR 10 3 6 Handling and Storage 3 7 4 Performance Verification Introduction 4 2 How Agilent Verifies the Devices in Your Kit 4 2 Recertificatio...

Страница 6: ...vi 11645A Contents ...

Страница 7: ...11645A 1 1 1 General Information ...

Страница 8: ... mismatch airline 50Ω airline data disks that contain factory measured verification data of the devices in the verification kit NOTE Backup copies of the verification data disks should be made immediately upon receipt of the this kit Refer to your analyzers user s guide for instructions on duplicating a disk Refer to Chapter 6 Replaceable Parts for a complete list of kit contents and their associa...

Страница 9: ...propriate parts tables in Chapter 6 Use Table 1 1 to record the serial numbers of all serialized devices in your kit Check for damage The foam lined storage case provides protection during shipping Verify that this case and its contents are not damaged If the case or any device appears damaged or if the shipment is incomplete refer to Contacting Agilent on page 5 5 Agilent will arrange for repair ...

Страница 10: ...the integrity of the devices in this kit include routine visual inspection routine cleaning proper connection techniques All of these are described in Chapter 3 Failure to detect and remove dirt or metallic particles can degrade repeatability and accuracy and can damage any mating surface connected to it Improper connections can also damage these devices Table 1 1 Serial Number Record Device Seria...

Страница 11: ...11645A 2 1 2 Specifications ...

Страница 12: ...rameter Required Values Ranges Temperature Operatinga a The temperature range over which the calibration standards maintain conformance to their specifications 20 C to 26 C 68 F to 79 F Error corrected rangeb b The allowable network analyzer ambient temperature drift during measurement calibration and during measurements when the network analyzer error correction is turned on Also the range over w...

Страница 13: ...ification device the S parameter measurement data for the device the measurement uncertainties of the system on which the device was measured The factory measured data for each device is supplied with your kit in print form and on disk Certification Agilent Technologies certifies that this product met its published specifications at the time of shipment from the factory Agilent further certifies t...

Страница 14: ...2 4 11645A Specifications Electrical Specifications ...

Страница 15: ...11645A 3 1 3 Use Maintenance and Care of the Devices ...

Страница 16: ...use a grounded conductive table mat while making connections always wear a heel strap when working in an area with a conductive floor If you are uncertain about the conductivity of your floor wear a heel strap always ground yourself before you clean inspect or make a connection to a static sensitive device or test port You can for example grasp the grounded outer shell of the test port or cable co...

Страница 17: ...ears and degrades The wear is greatly accelerated when mating surfaces are not kept clean or are not connected properly Mating surfacer wear eventually degrades performance of the device Calibration devices should have a long life if their use is on the order of a few times per week Replace devices with worn mating surfaces The test port connectors on the network analyzer test set may have many co...

Страница 18: ...nformation WARNING Keep isopropyl alcohol away from heat sparks and flame Store in a tightly closed container It is extremely flammable In case of fire use alcohol foam dry chemical or carbon dioxide water may be ineffective Use isopropyl alcohol with adequate ventilation and avoid contact with eyes skin and clothing It causes skin irritation may cause eye damage and is harmful if swallowed or inh...

Страница 19: ...onnect R band WR 28 Always connect the waveguide with the same flange orientation For example always connect a device with the label facing the same direction Follow theses recommendations for optimum connection technique 1 Place two alignment pins with heads in opposite holes of each flange For example one in the top left and one in the bottom right 2 Using the pins as guides carefully align the ...

Страница 20: ...ers when connecting Q U V or W band waveguide The flanges have tapped screw holes captive screws threaded half way up the shaft are provided in these kits Follow these recommendation for optimum connection technique 1 Install four captive screws into the test port 2 Install the alignment pins 3 Using the pins as a guide bring the flanges together and gently engage the first few threads of each scr...

Страница 21: ...o not store devices loose in a box or in a desk or bench drawer This is the most common cause of damage during storage Do not touch mating plane surfaces Natural skin oils and microscopic particles of dirt are easily transferred to a the interface and are very difficult to remove Do not set devices contact end down on a hard surface The plating and the mating plane surfaces can be damaged if the i...

Страница 22: ...3 8 11645A Use Maintenance and Care of the Devices Handling and Storage ...

Страница 23: ...11645A 4 1 4 Performance Verification ...

Страница 24: ...ments and material properties are carefully modeled to give very accurate electrical representation The mechanical measurements are then traced to NIST through various plug and ring gages and other mechanical measurements 2 Each device is electrically tested on this system For the initial before sale testing of the devices Agilent includes the test measurement uncertainty as a guardband to guarant...

Страница 25: ...ies Refer to Contacting Agilent on page 5 5 How Often to Recertify The suggested initial interval for recertification is 12 months or sooner The actual need for recertification depends on the use of the kit After reviewing the results of the initial recertification you may establish a different recertification interval that reflects the usage and wear of the kit NOTE The recertification interval s...

Страница 26: ...4 4 11645A Performance Verification Recertification ...

Страница 27: ...11645A 5 1 5 Troubleshooting ...

Страница 28: ...d information about network analyzer system operation For complete information refer to the instrument documentation If your network analyzer does not pass performance verification follow the steps in Figure 5 1 to determine the cause of the failure and the correct action to take to correct the failure ...

Страница 29: ...11645A 5 3 Troubleshooting Troubleshooting Process Figure 5 1 Troubleshooting Flowchart ...

Страница 30: ...contact person within your company and the person s complete telephone number including country code and area code the model number and serial number of the kit if returning a complete kit the part number and serial number of each device being returned the type of service required a detailed description of the problem if applicable and how the device was being used when the problem occurred Where ...

Страница 31: ...820 87 44 11 fax 0820 87 44 22 Belgium tel 32 0 2 404 9340 alt 32 0 2 404 9000 fax 32 0 2 404 9395 Denmark tel 45 7013 1515 alt 45 7013 7313 fax 45 7013 1555 Finland tel 358 10 855 2100 fax 358 0 10 855 2923 France tel 0825 010 700 alt 33 0 1 6453 5623 fax 0825 010 701 Germany tel 01805 24 6333 alt 01805 24 6330 fax 01805 24 6336 Ireland tel 353 0 1 890 924 204 alt 353 0 1 890 924 206 fax 353 0 1 ...

Страница 32: ...5 6 11645A Troubleshooting Contacting Agilent ...

Страница 33: ...11645A 6 1 6 Replaceable Parts ...

Страница 34: ...it Agilent Part Number Attenuators 20 dB attenuator with data 1 11645 60021 50 dB attenuator with data 1 11645 60022 Airlines 50Ω airline with data 1 11645 60016 25Ω mismatch airline with data 1 11645 60011 Miscellaneous Items Disk holder 1 5180 8491 Pad 1 11645 80026 Storage case 1 5181 5517 Storage box assembly 1 1540 0034 User s and service guide 1 11645 90013a a See Printing Copies of Document...

Страница 35: ...11645A 6 3 Replaceable Parts Introduction Figure 6 1 R Band Component Identification Sheet ...

Страница 36: ...27 Storage case 1 5181 5517 Storage box assembly 1 1540 0034 User s and service guide 1 11645 90013a a See Printing Copies of Documentation from the Web on page iii Verification data disk 8510 1 11645 10007 Verification data disk PNA 1 11645 10020 Specification and performance verification disk 1 08510 10033 Connector care quick reference card 1 08510 90360 Hardware Waveguide Alignment Pin short 6...

Страница 37: ...11645A 6 5 Replaceable Parts Introduction Figure 6 2 Q Band Component Identification Sheet ...

Страница 38: ...27 Storage case 1 5181 5517 Storage box assembly 1 1540 0034 User s and service guide 1 11645 90013a a See Printing Copies of Documentation from the Web on page iii Verification data disk 8510 1 11645 10008 Verification data disk PNA 1 11645 10021 Specification and performance verification disk 1 08510 10033 Connector care quick reference card 1 08510 90360 Hardware Waveguide Alignment Pin short 6...

Страница 39: ...11645A 6 7 Replaceable Parts Introduction Figure 6 3 U Band Component Identification Sheet ...

Страница 40: ...0 8491 Pad 1 11645 80028 Storage case 1 5181 5517 Storage box assembly 1 1540 0034 User s and service guide 1 11645 90013a a See Printing Copies of Documentation from the Web on page iii Verification data disk 8510 1 11645 10009 Verification data disk PNA 1 11645 10022 Specification and performance verification disk 1 08510 10033 Connector care quick reference card 1 08510 90360 Hardware Waveguide...

Страница 41: ...11645A 6 9 Replaceable Parts Introduction Figure 6 4 V Band Component Identification Sheet ...

Страница 42: ...80 8491 Pad 1 11645 80028 Storage case 1 5181 5517 Storage box assembly 1 1540 0034 User s and service guide 1 11645 90013a a See Printing Copies of Documentation from the Web on page iii Verification data disk 8510 1 11645 10010 Verification data disk PNA 1 11645 10023 Specification and performance verification disk 1 08510 10033 Connector care quick reference card 1 08510 90360 Hardware Waveguid...

Страница 43: ...11645A 6 11 Replaceable Parts Introduction Figure 6 5 W Band Component Identification Sheet ...

Страница 44: ... Part Number ESD Protection Devices Grounding wrist strap 1 9300 1367 5 ft grounding cord for wrist strap 1 9300 0980 2 x 4 ft conductive table mat and 15 ft ground wire 1 9300 0797 ESD heel strap for conductive floors 1 9300 1308 Connector Cleaning Supplies Isopropyl alcohol 30 ml 8500 5344 Cleaning swabs 100 9301 1243 ...

Страница 45: ... specifications 2 3 certification of 2 3 electrical 2 3 environmental 2 2 traceability 4 2 4 3 storage 3 7 temperature 2 2 disk verification part number 6 2 6 4 6 6 6 8 6 10 documentation part number 6 2 6 6 6 10 6 12 E electrical characteristics effects of temperature 2 2 electrical specifications 2 3 electrostatic discharge 3 2 environmental regulations 3 4 requirements 2 2 specifications 2 2 eq...

Страница 46: ...ing complete 1 3 specifications certification of 2 3 device 2 3 electrical 2 3 environmental 2 2 traceability 4 2 4 3 standard calibration 4 3 standards international 2 3 National Institute of Standards and Technology NIST 2 3 4 2 static discharge 3 2 storage 3 7 storage case part number 6 2 6 4 6 6 6 8 6 10 strap heel and wrist part number 6 12 supplies cleaning 1 3 part numbers 6 12 T tag servic...

Отзывы: