88
7713397 R2
Note
The outlet sensor/sample housing may be left-hand, center, or right-hand mounted onto the rear cross
auger system.
Figure 107.
Outlet Sensor and Sample Button Locations
#059243 SAMPLE BUTTON
NOTE:
AUGER STYLE DISCHARGE SHOWN
SAMPLE
SAMPLE
4.7.8 Install the Discharge Chute Cables
1. The gearmotor on the discharge chute comes pre-wired to a small capacitor box. Mount the box in a
convenient location, ideally under the dryer or under the cross auger/drag.
2. Connect the yellow “Sensor Motor” cable from the control panel to the capacitor box.
3. Dryers with auger unloads use a proximity switch (059118) to detect a plugged discharge, and dryers with
drag unloads use a diaphragm switch (059245) for this purpose. Install the appropriate switch as shown, and
connect the yellow “Plug Switch” cable from the control panel.
Figure 108.
Plug Switch Auger
7716112
CONTINUOUS-FLOW GRAIN DRYER – COMMANDER CONTROL