7713397 R2
61
Figure 57.
Anchor the Panel Support Legs
7715846
4.6.5 Stack and Secure Sections
Do NOT stack any additional sections on top of the bottom section unless it is secured to the
foundation.
Important
The following stacking information is applicable for:
•
Upper dryer sections made up of three to six tier levels.
•
Top-most filling dryer section made up of one or two tier levels and the topside filling system.
Note
All styles of fill systems, including catwalks and/or safety cages, should be completely assembled on the
ground and then lifted into position and secured.
Overview
1. Refer to the information contained in
Section 2. – Features on page 17
and
Section 6.1 – Dryer Tier / Ladder
/ Shipping Layouts on page 111
for specifics on layout and stacking order.
2. Depending on the dryer model configuration, some parts are installed at the factory whereas other parts
require installation as the sections are stacked.
3. STACKING ORDER: If your dryer has multiple sections, be sure to stack the sections in the proper order. Each
section has a decal indicating the section number, located just under the flanges below the burner box.
Section #1 is the top section. If the decals cannot be located, the motor lead length is also an indicator of
order, with the longest motor lead corresponding to the top section.
CONTINUOUS-FLOW GRAIN DRYER – COMMANDER CONTROL
Содержание NECO D16106
Страница 2: ......
Страница 4: ...4 7713397 R2 CONTINUOUS FLOW GRAIN DRYER COMMANDER CONTROL...
Страница 121: ...7713397 R2 121 CONTINUOUS FLOW GRAIN DRYER COMMANDER CONTROL 8 LIMITED WARRANTY...