54
7713397 R2
4.6. Install Dryer
Check and verify all anchor attachment systems are tight and correctly installed according to
the anchor manufacturer's specifications before adding any upper dryer sections or installing
leg kit (when supplied).
4.6.1 Position Lower Dryer Section at Location
1. Position the lower dryer section at the final location.
2. Be sure to support the lower section using a crane or setting it on temporary blocks, etc.
Figure 47.
Positioning the Lower Dryer Section
4.6.2 Install NECO Leg Kit
Be sure to support the dryer’s lower section assembly by hanging from a crane or sitting on
blocks prior to installing ANY support legs.
Leg Styles and Location
• “A” Side legs are located around the outside & inside perimeter of the dryer.
• “B” Center leg is located under the dryer at the front (blower) end.
• “C” Column legs (if needed) are located to provide column support for the platforms.
CONTINUOUS-FLOW GRAIN DRYER – COMMANDER CONTROL