AGFA CR Скачать руководство пользователя страница 1

CR User Station

User manual

Содержание CR

Страница 1: ...CR User Station User manual ...

Страница 2: ...ransmitted in any form or by any means without the written permission of Agfa Gevaert N V Agfa Gevaert N V makes no warranties or representation expressed or implied with respect to the accuracy completeness or usefulness of the information contained in this document and specifically disclaims warranties of suitability for any particular purpose Agfa Gevaert N V shall under no circumstances be lia...

Страница 3: ...General safety instructions 12 Safety precautions for the monitor 13 Safety instructions for cleaning the CR User Station 13 Safety compliance 14 Equipment for the CR Operator Console 15 Switching ON the ID Tablet 17 ID Software 18 Inserting cassettes 19 Appendix A Technical specifications 21 Technical Specifications for the CR User Station and included equipment 22 Technical Specifications for th...

Страница 4: ...4 2313B EN 20041109 CR USER STATION ...

Страница 5: ...e following topics Components of the CR User Station Positioning of the CR User Station Possible configurations Safety precautions Safety compliance Equipment for the CR Operator Console Switching ON the ID Tablet ID Software Inserting cassettes Chapter 1 ...

Страница 6: ...or up to 6 cassettes Two side storage racks for up to 5 cassettes each Foam tapes to be glued around the right side of the CR User Station if connected to the CR 25 0 Digitizer in order to avoid shock transmission The figure below is an example The actual outlook may vary as technology progresses not included with standard CR User Station if combined with a CR 25 0 Digitizer CR User Station compon...

Страница 7: ...ys As stand alone Combined with a Digitizer The CR User Station can be combined with the Digitizer CR 25 0 and the ADC Solo When combined with a Digitizer the CR User Station is always positioned at the left side It is not attached to the Digitizer so it can be removed easily for service purposes CR User Station stand alone CR User Station with Digitizer ...

Страница 8: ...ing image The ID Station can be used in three distinct configurations Dedicated Configuration Configuration with a server The CR User Station and the Digitizer are dedicated to one Server Interchangeable Configuration Configuration with client or server PC The CR User Station can serve a range of Digitizers Configuration with Direct ID Configuration with a server PC that is dedicated to one Digiti...

Страница 9: ... e g CR 25 0 an optimal workflow can be reached The cassette is first identified with the included ID Tablet and is inserted in the Digitizer afterwards The dedicated configuration reduces the time required for the identification of the cassette the scanning and the view of the images because all actions can be performed in the same room Digitizer CR User Station with ID Tablet Dedicated Configura...

Страница 10: ... cassette As a result the identification data are linked to the cassette and any Digitizer can be used to scan the cassette This configuration allows the flexible use of several Digitizers and CR User Stations depending on the workload The transmission of the identification data to the cassette chip takes place when you insert the cassette into the transmission slot of the CR User Station s ID Tab...

Страница 11: ...ne ID Station and the ID data is transmitted via the network This configuration reduces identification time and scanning of the cassette because both actions can be performed simultaneously In this configuration you can still use the Digitizer to scan cassettes which have been identified via the ID Tablet on a CR User Station or an ID station Digitizer ID Station without ID Tablet Configuration wi...

Страница 12: ...on than those described in this document Pay attention when working near the pedestal the foot projects slightly and could be tripped on When rolling the pedestal away from its position take care not to pull or put any strain on power or network leads When moving the CR User Station take care that it remains stable at all times In particular the following considerations should be kept in mind the ...

Страница 13: ... is not connected to a CR 25 0 Digitizer as shown below Safety precautions for the monitor The monitor must be fixed on the monitor arm with screws If the monitor arm is re positioned in a different height the lock must be closed Safety instructions for cleaning the CR User Station Pull the power plug out of the CR User Station prior to cleaning the equipment and switch off the UPS Uninterruptible...

Страница 14: ... the federal code of the United States bearing on Emission and immunity according to EN 60601 1 2 for emissions the equipment complies with EN 55011 class A CISPR 11 This is a Class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures Emissions according to 47 CFR part 15 subpart B Class A This equipment has ...

Страница 15: ...General instructions The CR User Station and the equipment will be installed and configured by an Agfa service technician If you use non AGFA equipment make sure that the dimensions and technical specifications are compatible with the CR User Station All equipment of the CR User Station must be connected to the transformer via UPS if available not included must be ordered separately Front side Bac...

Страница 16: ...talled for the identification of the cassettes refer to ID Software on page 18 It can also be used for the QS Software that is necessary for the image processing Network Switch Network Switch for several network connections e g the Digitizer to the PC printers etc UPS Uninterruptible Power Supply The UPS for the PC is an Uninterruptible Power Supply that protects the PC when the main power supply ...

Страница 17: ...er Station CR USER STATION Switching ON the ID Tablet The ID Tablet can be switched on by pushing the green Power ON button at the end of the slot of the ID Tablet This also functions as the Reset button for the ID Tablet Switch ON Reset button ...

Страница 18: ...R STATION ID Software The ID Software is used to insert the patient demographics and the examination data in a study orientated manner Afterwards this data is written into the memory chip of the cassette Refer to the ADC QS ID Viewer Software Online Help manual ...

Страница 19: ...ettes The cassettes will be inserted in the ID Tablet in a different way than they are dropped into the Digitizer The black tube side is pointed to the left The label is at the right hand side farthest from you and pointed downwards 35x43 35x35 24x30 10x12 18x24 8x10 Locking mechanism ...

Страница 20: ...r they must be turned 90 so that the locking mechanism is at the bottom The black tube side is still pointed to the left Some cassettes will be inserted in the ID Tablet in the same manner as they are dropped into the Digitizer 35x43 35x35 24x30 10x12 18x24 8x10 Locking mechanism 24x30 mammo 18x24 mammo 15x30 Locking mechanism ...

Страница 21: ...Technical specifications Appendix A ...

Страница 22: ...ease consult your local sales organization Dimensions Height 1010 mm Height with monitor arm and 19 monitor max 1710 mm Width without cassette rack 320 mm Depth 650 mm Footprint 540 mm x 650 mm docked to CR 25 0 Digitizer 640 mm x 650 mm stand alone version Weight 53 kg empty ca 100 kg fully equipped Operating conditions Temperature 10 C 30 C Temperature change 0 5 C min Humidity 15 RH to 80 RH Te...

Страница 23: ...w blow 230 240 V 2 5 A slow blow Secondary 230 V 2 0 A slow blow Technical specifications of the ID Tablet Working voltage for the wall power supply 100 240 V AC 5 V DC Frequency 50 60 Hz Classification Class III The ID Tablet is provided with 1 power input 5 V DC and 1 RS232 input The equipment is suited for continuous operation ...

Страница 24: ... x D Technical specifications of the UPS buffers PC Switch and monitor Type recommended Powerware 5115 750i Dimensions max 185 mm x 150 mm x 333 mm H x W x D Power rating 500 1400 VA Voltage output 220 240 V AC Technical specifications of the Switch Type recommended Dell Powerconnect 2616 10 100 Mbit auto sense 8 or 16 plugs Dimensions max 44 mm x 266 mm x 162 mm H x W x D Technical specifications...

Страница 25: ...Remarks for HF emission and immunity Appendix B ...

Страница 26: ...ement Electromagnetic Environment Guidelines High frequency transmissions in accordance with CISPR 11 Group 1 The device uses high frequency energy exclusively for its internal functions For this reason its high frequency transmission is very low and it is improbable that neighboring electronic equipment will be disrupted High frequency transmissions in accordance with CISPR 11 Class B The device ...

Страница 27: ... kV common mode voltage 1 kV push pull voltage 2 kV common mode voltage The quality of the voltage supplied should correspond to that of a typical commercial or clinical environment Voltage breakthroughs short term interruptions and variations in the voltage supplied in accordance with IEC 61000 4 11 5 Ur 95 breakthrough of Ur for period 40 Ur 60 breakthrough of Ur for 5 periods 70 Ur 30 breakthro...

Страница 28: ...transmission frequency Recommended protective distance Conducted high frequency disturbance variables in accordance with IEC 61000 4 6 3 Veff 150 kHz to 80 MHz 3 Veff d 1 2 Radiated high frequency disturbance variables in accordance with IEC 61000 4 3 3 V m 80 MHz to 2 5 GHz 3 V m d 1 2 80 MHz to 800 MHz d 2 3 800 MHz to 2 5 GHz With P as the rated power of the transmitter in watts W in accordance...

Страница 29: ...stations and AM and FM radio transmitters cannot be precisely predetermined theoretically An investigation of the location is recommended to ascertain the electromagnetic environment as a result of stationary high frequency transmitters If the field strength of the device exceeds the level of agreement given above the device must be observed with regard to its normal operation at each place of use...

Страница 30: ... m 150 kHz to 80 MHz d 1 2 80 MHz to 800 MHz d 1 2 800 MHz to 2 5 GHz d 2 3 0 01 0 12 0 12 0 23 0 1 0 38 0 38 0 73 1 1 2 1 2 2 3 10 3 8 3 8 7 3 100 12 12 23 The distance can be determined through the equation for each respective column P is the rated power of the transmitter in watts W according to the manufacturer information on the transmitter only for transmitters where the rated power is not m...

Страница 31: ...31 2313B EN 20041109 Remarks for HF emission and immunity CR USER STATION ...

Страница 32: ...Printed in Belgium Published by Agfa Gevaert N V B 2640 Mortsel Belgium 2313B EN 20041109 ...

Отзывы: