© Copyright LOTRONIC 2012 IPAR-136
Page 3
MOUNTING
Orientation
This
fixture
may
be
mounted
in
any
position,
provided
there
is
adequate
room
for
ventilation
When
selecting
installation
location,
take
into
consideration
lamp
replacement
access
and
routine
maintenance.
Safety
cables
must
always
be
used.
Never
mount
in
places
where
the
fixture
will
be
exposed
to
rain,
high
humidity,
extreme
temperature
changes
or
restricted
ventilation.
If
the
external
flexible
cable
or
cord
of
this
light
is
damaged,
it
shall
be
exclusively
replaced
by
the
manufacturer
or
his
service
agent
or
a
similar
qualified
person
in
order
to
avoid
a
hazard.
Make
sure
the
installation
position
is
stable
before
you
fix
the
light.
When
the
light
is
reverse
hanging,
make
sure
the
light
will
not
fall
from
the
truss,
use
the
safety
cable
go
through
the
truss
and
bracket
of
the
light
as
a
supporting,
to
avoid
the
light
to
fall
down.
There
is
no
entrance
to
the
work
area
during
mounting.
Periodically
check
if
the
safety
cable
has
fretted
away
or
clamp
is
loosened.
We
will
not
take
any
responsibility
for
damages
caused
by
a
badly
installed
unit.
Power
Supply
and
Signal
Cable
Connection
1.
Mains
Power
connection
The
exclusive
plug
should
be
used
between
the
connection
of
unit
and
power.
Please
ensure
that
the
rated
voltage
and
frequency
are
accordance
with
the
power
supply.
The
required
input
voltage
and
frequency
are:
100
‐
240VAC
We
suggest
that
every
light
has
an
independent
switch
so
that
you
can
turn
on
or
turn
off
the
light
randomly.
Note:
the
ground
wire
(yellow/green
double
‐
color
wire)
must
be
safely
connected,
the
electrical
installation
must
be
in
accordance
with
the
related
standards
CAUTION
:
When
installing
the
device,
make
sure
there
is
no
highly
inflammable
material
within
a
distance
of
min.5m!
2.
Connection
of
Signal
Cable
You
can
use
the
3
‐
pin
XLR
cable
to
connect
the
output
socket
of
the
master
and
the
input
socket
of
the
slave
light.
Connect
the
DIGITAL
OUT
socket
of
the
master
and
the
IN
socket
of
the
slave
light,
then,
connect
the
OUT
socket
to
the
IN
socket
of
the
next
light.
Ordinal
to
connect
all
the
lights
as
below:
IN
O U T
IN
O U T
O U T
IN
1
2
3
D
M
X
I
N
D
M
X
O
U
T
The
connection
between
the
output
of
master
and
input
of
product,
it’s
available
to
use
the
3
pins
XLR
cable
which
provided
by
the
manufacturer.
Signal
cable
from
the
DMX
output
of
the
controller
to
the
input
of
the
first
master
light,
and
connect
to
the
DMX
input
of
second
slave
light
from
the
DMX
output
of
the
first
master
light,
analogously,
till
connected
all
the
slave
lights,
and
insert
the
last
connector
to
the
output
of
the
final
light.
(Notice:
the
diameter
of
core
of
every
cable
should
be
0.5mm
at
least,
double
core
shelter
cable
should
be
used).The
signal
connecting
must
use
the
attached
3
pins
XLR
cable.
Notice,
all
the
internal
lead
wire
of
the
3
pins
XLR
cable
should
not
touch
to
each
other
or
connect
to
the
connector.
A
DMX
signal
terminator
is
recommended
on
the
last
unit
of
the
chain.
DMX
terminator
is
a
XLR
connector
with
a
120
Ω
resistor
between
the
pin
2
and
pin
3
of
the
XLR
connector