Safety Precautions 

 

Read all safety precautions and installation instructions carefully before installing or servicing this fixture. Failure to comply with these instructions could result in 
potentially fatal electric shock and/or property damage. 

 

It is recommended that a qualified electrician perform all wiring. This fixture must be wired in accordance with all national and local electrical codes. 

 

Do not handle any energized fixture or attempt to energize any fixture with wet hands or while standing on a wet or damp surface or in water. 

 

This fixture is designed for use in a 120-277VAC, 60Hz fused circuit and can be used in conjunction with 0-10V dimmers. 

 

To reduce the risk of electrical shock, and to assure proper operation, this fixture must be adequately grounded. To accomplish proper grounding, there must be a 
separate ground wire (green) contact between this fixture and the ground connection of your main power supply panel.  

 

This fixture is intended to be used for general indoor or outdoor lighting in dry, damp or wet locations. For wet locations, fixture must be mounted at least 48 inches 
above ground level. 

 

Disclaimer 
Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. NOTE: This 
equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules and Canadian ICES-005 (B) / NMB-005 
(B). These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate 
radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no 
guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be 
determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: 

• Reorient or relocate the receiver antenna. 
• Increase the separation between the equipment and receiver. 
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. 
• Consult with the dealer or an experienced radio/TV technician for help. 

Any modifications to this fixture may void the warranty and interfere with the safe operation of the luminaire.  
Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference 
that may cause undesired operation of the device.

 

Assembly Instructions 

 

1.  Preparing for installation, refer to Figs. 2/3/4. 

A. 

Disconnect electrical power

 before installing or servicing any part of this fixture.

 

B. 

Remove all parts and parts bags from carton. 

C. 

Note this fixture is suitable for Reversible installation – Top to Bottom. 

D. 

Separate fixture back pan (5), mounting bracket (2) and fixture diffuser (7).

 

E. 

Install mounting bracket (2) to junction box (not included) with two #8-32 screws (4). 

 

F. 

For 

BDWW041423LAJD2xx,

 

proceed to Step 2.

 

G.  For 

BDWW072033LAJD2xx & BDWW083035LAJD2xx,

 temporary mount back pan (5) to the mounting bracket and mark top and bottom 

hole (9) with pencil. Remove back pan and drill appropriate size holes for plastic anchors (11) if used over drywall or small pilot holes if going 
into wood. 

 

 
(Note: BDWW041423LAJD2xx fixture does not require mounting slots, screws and plastic 
anchors not provided.)

 

 

2.  Color Temperature (CCT) Adjustment (if desired), refer to Fig.1. 

A. 

In rear of fixture, locate CCT Dip Switches. 

B. 

Adjust two switches to desired color temp as shown at right, choose 3000K, 3500K or 4000K.   

C. 

Note: 

Fixture is preset to 3500K from factory. 

 

3.  Wiring.

 

All wiring must take place inside junction box.

 

Caution:

 Make sure power is off at fuse or circuit breaker box. Check power wires for damage or 

scrapes. If power supply wires are within three inches of driver use wire suitable for at least 90°C 
(194°F). 

Note:

 Most dwellings built before 1985 have supply wire rated to 60°C. Consult a qualified 

electrician before installing. 
A. 

This unit will not operate properly unless connected to a “grounded” electrical circuit. Electrical 
shock, overheating, low or no light output, and shortened LED life can result if proper grounding 
is not done. Securely attach power source ground wire and fixture copper ground wire to green 
ground screw on mounting bracket. 

B. 

Make all wire connections to appropriate wire. Secure with wire nuts (provided). 

C. 

For Non-dimming.

 Fixture will operate normally w/o a connection to a dimmer. Connect white 

fixture lead to white (N) wire from supply power source. Connect black fixture lead to black (L) 
wire from supply power source.  Make sure to cap gray and purple wires separately to prevent 
shorting. 

D. 

For 0-10V dimming.

 Connect grey wire from the fixture to the dimmer source grey wire. Connect purple wire from the fixture to the dimmer 

source purple wire. Connect white fixture lead to white (N) wire from supply power source. Connect black fixture lead to black (L) wire from 
supply power source. 

E. 

Do not mix wires

. Pull on each wire lead to make sure connections are secure. Make certain no bare wires are exposed outside of wire 