Operating instructions

 

74363 Güglingen 

 

Fon: +49 7135 102-0  

 

Service: +49 7135 102-211  

 

[email protected]m

  

probes

 

www.afriso.com 

DMU 08, DMU 08 T, DMU 09

 

 

 

 

 

 

ID: 900.100.0832 Version: 10.2021.0  

1. General and Safety-Related Information on 

this Operating Manual 

This operating manual enables safe and proper 

handling of the product.  

This operating manual forms part of the device and 

should be kept in close proximity to the place of use, 

accessible for staff members at any time.  
All persons entrusted with the mounting, installation, 

putting into service, operation, maintenance, 

removal from service, and disposal of the device 

must have read and understood the operating 

manual and in particular the safety-related 

information.  
 

The following documents

 

are an important part 

of the operating manual: 

Data sheet 

For specific data on the individual sensors, please 

refer to the respective data sheet. 
Download these by accessing www.afriso.com or 

request them by e-mail or phone: [email protected]

In addition, the applicable accident prevention 

regulations, safety requirements, and country-

specific installation standards as well as the 

accepted engineering standards must be observed. 

 

1.1 Symbols Used 

 

Warning word

 

-  Type and source of danger 

-  Measures to avoid the 

danger 

 

Warning word

 

Meaning

 

 

DANGER

 

-  Imminent danger! 

-  Non-compliance 

will 

result in

 death or serious 

injury. 

 

WARNING

 

-  Possible danger! 

-  Non-compliance 

may 

result in

 death or serious 

injury. 

 

 CAUTION 

 

 

-  Hazardous situation! 

-  Non-compliance 

may result 

in

 minor or moderate injury. 

NOTE

 – draws attention to a possibly hazardous 

situation that may result in property damage in case 

of non-compliance.  

 

Precondition of an action

 

1.2 Staff Qualification 
Qualified persons 

are persons that are familiar with 

the mounting, installation, putting into service, 

operation, maintenance, removal from service, and 

disposal of the product, and have the appropriate 

qualification for their activity. 

 

This includes persons that meet at least one of the 

following three requirements: 

They know the safety concepts of 

metrology and automation technology and 

are familiar therewith as project staff. 

They are operating staff of the measuring 

and automation systems and have been 

instructed in the handling of the systems. 

They are familiar with the operation of the 

devices and technologies described in this 

documentation. 

They are commissioning specialists or are 

employed in the service department, and 

have completed training that qualifies 

them for the repair of the system. In 

addition, they are authorized to put into 

operation, to ground, and to mark circuits 

and devices according to the safety 

engineering standards.  

All work with this product must be carried out by 

qualified persons! 

1.3 Intended Use

 

The 

probes

 are exclusively suitable for continuous 

hydrostatic filling-level measurement. 
The user must check whether the device is suited 

for the selected use. In case of doubt, please 

contact our sales department ([email protected]). 

AFRISO assumes no liability for any wrong selection 

and the consequences thereof! 
The fluids that can be measured are liquids that are 

compatible with the materials in contact with the 

fluids, described in the data sheet. For application, it 

must additionally be ensured that the fluid is 

compatible with the parts in contact with the fluid. 
The specifications listed in the current data sheet 

are binding and must absolutely be complied with. If 

you do not have the data sheet to hand, please 

request it or download it from our homepage. 

(http://www.afriso.de) 

1.4 Limitation of Liability and Warranty 

Failure to observe the instructions or technical 

regulations, improper use and use not as intended, 

and alteration of or damage to the device will result 

in the forfeiture of warranty and liability claims. 

1.5 Safe Handling 
NOTE  – 

Treat the device with care both in the 

packed and unpacked condition! 

 

NOTE –

 The device must not be altered or modified 

in any way.  

 

NOTE –

 Do not throw or drop the device! 

NOTE  – 

Excessive dust accumulation (over 5 mm) 

and complete coverage with dust must be 

prevented! 
The device is state-of-the-art and is operationally 

reliable. Residual hazards may originate from the 

device if it is used or operated improperly. 

1.6 Packaging Content 

Check that all parts listed in the scope of delivery 

are included free of damage, and have been 

delivered according to your purchase order: 
 

-  probe 
-  operating manual 

2. Product Identification 

The device can be identified by means of the type 

plate with order code. The most important data can 

be gathered therefrom. 

 

1

  Type designation 

4

  Order code

 

 

2

  Input 

5

  Terminal assignment 

3

  Output 

6

  Serial number  

Fig. 1: Type plate

  

NOTE

 – The type plate must not be removed! 

3. Mounting 

3.1 Mounting and Safety Instructions 

WARNING 

airborne parts, leaking fluid, 

electric shock  

-  Always mount the device in a 

depressurized and de-

energized condition! 

NOTE – 

If there is increased risk of damage to the 

device by lightning strike or overvoltage, increased 

lightning protection must additionally be provided! 

NOTE – 

Install the probe such that any rubbing or 

bumping of the sensor head (sensor element), e.g. 

against a container wall, is excluded. Observe the 

operating conditions such as, for example, flow 

conditions. This applies in particular to probes 

equipped with cable outlet and to devices with tube 

extensions of a length over 2.8 m. 

NOTE

 – Do not remove the packaging or protective 

caps of the device until shortly before the mounting 

procedure, in order to exclude any damage to the 

diaphragm and the threads!  
Protective caps must be kept! Dispose of the 

packaging properly!  

NOTE – 

Treat any unprotected diaphragm with 

utmost care; this can be damaged very easily. 

3.2 Mounting Steps for Probes 
NOTE 

– Always immerse the device slowly into the 

fluid to be measured! If the probe strikes the liquid 

surface, the diaphragm could be damaged or 

destroyed. 

NOTE – 

Fasten the probe properly according to your 

requirements. 

NOTE –

 Free-hanging probes with FEP cables 

should not be used if effects of highly charging 

processes can be expected. 

As standard, the probe is supplied without fastening 

material. Clamp fixing, anchor clamp and mounting 

flanges are available as accessories, for different 

mounting variants. 

3.3 Mounting Steps for fitting set  

 

The mounting thread is clean and undamaged 

 

The O-ring is undamaged and seated in the 

designated groove 

1.  Assemble suitable parts according to demands. 
2.  Conduct the Cable by the PG11 screw 

connection. Note the submersion depth in the 

container. 

3.  Then tighten the single parts of the fitting set by 

hand. 
 

If you need a fitting set, this can be ordered from 

AFRISO as an accessory (Art. No. 52125). 

3.4 Removal of Protective Cap (if equipped) 

The probes are equipped with a plastic protective 

cap to protect the diaphragm. This has to be pulled 

off prior to putting into service if the probe is to be 

used in a higher viscous fluid such as sludge. This 

makes the probe front-flush, and the fluid reaches 

the diaphragm. 

Removal by hand 

1.  Hold the probe such that the protective cap 

points upward. 

2.  Hold the probe with one hand on the probe 

section  

(Fig. 2 – 1).  

3.  Pull off the protective cap (Fig. 2 –  2) with the 

other hand. 

Removal using a tool (recommended) 

1.  Hold the probe such that the protective cap 

points upward. 

2.  Slide a thin tool (Fig. 2 – 8), e.g. a screwdriver, 

through two opposite bores of the protective cap 

(Fig. 2 – 2). 

3.  Lever off the protective cap. 

NOTE –

 Do not damage the measuring cell (Fig. 2 – 

7) under the protective cap! 

3.5 Cable Protection (Optional) 

According to order, the probe was supplied with 

cable protection; if the probe was prepared for 

mounting by means of a stainless steel or PVC tube 

(optional), the customer must affix a cable protection 

themselves.  

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fig. 3: Cable protection variants

 

4. Electrical Connection 

4.1 Connection and Safety Instructions 

WARNING 

Improper installation may result 

in electric shock 

-  Always mount the device in a 

depressurized and de-

energized condition! 

 
 
 

DANGER 

 

Explosion hazard if the 

operating voltage is too high 

(max. 28VDC)! 

Operate the device only within 

the specification! (data sheet)

 

 

The limit values listed in the EC type-

examination certificate are observed. 

(Capacity and inductance of the connection 

cable are not included in the values.) 

 

The supply corresponds to protection class II. 

(protective insulation) 

NOTE – 

for devices with 

cable outlet

  

-  When routing  the cable, the following minimum 

bend radii must be observed: 

 

Cable without air hose: 

 

 

fixed installation: 5-fold cable diameter 

 

 

flexible use: 10-fold cable diameter 

 

Cable with air hose: 

 

 

fixed installation: 10-fold cable diameter 

 

 

flexible use: 20-fold cable diameter 

-  In case of devices with 

cable outlet

  and 

integrated ventilation hose, the PTFE filter 

located at the cable end on the relative pressure 

hose must neither be damaged nor removed! 

NOTE –

 Use a shielded and twisted multicore cable 

for the electrical connection.

 

 

 

NOTE –

 If a transition is desired from a cable with 

relative pressure hose to a cable without relative 

pressure hose, we recommend using the terminal 

box with pressure equalizing port (Art. No. 31824). 

4.2 Electrical Installation

  

Connect the device electrically according to the 

information specified on the type plate, the following 

table, and the connection circuit diagram. 

Terminal assignment table: 

Electrical 

connections 

Cable colors 

(IEC 60757) 

 
Supply 

 

wh (white) 

bn (brown) 

Shield 

gnye (green-yellow) 

DMU 08 T 

Cable colors 

(IEC 60757) 

Supply P+ 

Supply P– 

Supply T+ 

Supply T– 

wh (white) 

bn (brown) 

gy (gray) 

pk (pink) 

Shield 

gnye (green-yellow) 

Connection circuit diagrams: 

2-wire system (power) 

2x2-wire-system (current) (DMU 08 T) 

NOTE –

 In the case of relative pressure gauges, the 

cable contains a ventilation hose for pressure 

equalization. Route the end of the cable into an area 

or suitable connection box which is as dry as 

possible and free from aggressive gases, in order to 

prevent any damage 

 

 

 

 

 

 

Supply – 

 

V

S

 

 

 

Fig. 2: Removal of protective cap 

Examples for cable protection 

with stainless steel tube 

Stainless 

steel 

corrugated 

tube 

Stainless 

steel or PVC 

tube 

withou

1                2             3         4                 5                  6  

supply 

P+ 

supply P- 

supply T+ 

supply T- 

V

S

 

p  

V

 

– 

– 