21
Commissioning
EN
DIT 10
6
Commissioning
Verify that all components are completely installed.
6.1
Entering the tank data
Zero calibration has been performed.
6.1.1
Adjusting the tank shape
The arrow at the bottom of the display points to the unit
Litres
.
The display shows the code of the selected tank shape.
- When the unit is commissioned for the first time, the displayed code
is
0
. Code
0
means that no tank shape has yet been selected.
1. Use the two programming keys to set the code of the tank shape deter-
mined (see chapter "Tank shape").
2. Press the function key to confirm the setting.
6.1.2
Tank volume
The arrow at the bottom of the display points to the unit
m³
.
The display shows the tank volume set.
- The value
0000
means that no tank volume has yet been entered.
1. Use the programming keys to enter the total volume of the tank facility
determined. Press the programming key (arrow up) to select the digit to
be changed. Then press the programming key (arrow down) to change
the value of the selected digit.
2. Up to a value of 9999 litres, the value is entered in litres without a dec-
imal place. In the case of volumes > 9999 litres, the value is entered in
cubic metres (1000 litres = 1 cubic metre) with a decimal place. Use
the programming key (arrow up) to move the decimal place.
3. Press the function key to confirm the setting.
Содержание DIT 10
Страница 28: ...28 Anhang DE DIT 10 14 Anhang 14 1 Konformitätserklärung Auswertegerät ...
Страница 29: ...29 Anhang DE DIT 10 14 2 Konformitätserklärung Tauchsonde ...
Страница 57: ...28 Appendix EN DIT 10 14 Appendix 14 1 Declaration of Conformity control unit ...
Страница 58: ...29 Appendix EN DIT 10 14 2 Declaration of Conformity submersible probe ...
Страница 86: ...28 Annexe FR DIT 10 14 Annexe 14 1 Déclaration de conformité unité de commande ...
Страница 87: ...29 Annexe FR DIT 10 14 2 Déclaration de conformité sonde à immersion ...
Страница 115: ...28 Aneks PL DIT 10 14 Aneks 14 1 Deklaracja zgodności analizatora ...
Страница 116: ...29 Aneks PL DIT 10 14 2 Deklaracja zgodności sondy zanurzeniowej ...