background image

 

Mounting and commissioning 

Unimes E 

15 

6.8 

Entering the tank data at the remote indicator 

 

Zero calibration has been performed. 

 

The pointer of the direct indication gauge points to 100 %. 

Tank shape 

 

The arrow at the bottom of the display points to the unit "Litres". 

 

The display shows the code of the selected tank shape. When 
the unit is commissioned for the first time, the displayed code is 
0. Code 0 means that no tank shape has yet been selected. 

1. 

Use the keys 

 and 

 to set the code of the tank shape deter-

mined. Refer to chapter 6.1, page 11. 

2. 

Press the F key to accept the setting and continue with the tank 
volume. 

Tank volume 

 

The arrow at the bottom of the display points to the unit m³. 

 

The display shows the currently selected tank volume. 0000 
means that no tank volume has yet been entered. 

1. 

Use the 

 and 

 keys to enter the total volume of the tank fa-

cility. By pressing the 

 key, you can select the digit to be 

changed. The 

 key allows you to change the selected digit 

within a range from 0 to 9. 

2. 

Up to a volume of 9999 litres, the volume is entered in litres 
without decimal places. In the case of volumes of > 9999 litres, 
the value is entered in cubic metres with a decimal place (1000 
litres = 1 cubic metre). The decimal place is moved with the 

 

key. 

3. 

Press the F key to accept the setting and continue with the tank 
height. 

Tank height 

 

The arrow at the bottom of the display points to the unit "Per-
cent". The display shows the currently selected tank height. 
0000 means that no tank height has yet been entered.  

1. 

Set the tank height in mm with the 

 keys: By pressing the 

 

key, you can select the digit to be changed. The 

 key allows 

you to change the selected digit within a range from 0 to 9. 

2. 

Press the F key to accept the setting and continue with the cur-
rent level. 

Содержание Unimes E

Страница 1: ... 49 0 7135 102 211 Telefax 49 0 7135 102 147 E Mail info afriso de Internet www afriso de Read instructions before using device Observe all safety information Keep instructions for future use Version 10 2007 Id no 854 001 0422 Operating Instructions Mechanical Tank Contents Gauge with Electronic Remote Indication Type Unimes E Part no 52130 ...

Страница 2: ... data 11 6 2 Mounting the wall bracket for the remote indicator 12 6 3 Adjusting the float 12 6 4 Adjusting the tank height at the direct indication gauge 12 6 5 Connecting the direct indication gauge and the remote indicator 13 6 6 Connecting the battery of the remote indicator 13 6 7 Zero point adjustment at the remote indicator 14 6 8 Entering the tank data at the remote indicator 15 6 9 Mounti...

Страница 3: ...Unimes E 3 10 Shutting down disposal 19 11 Spare parts and accessories 19 12 Warranty 20 13 Copyright 20 14 Customer satisfaction 20 15 Addresses 20 ...

Страница 4: ...here There are three different levels of warnings Warning term Meaning DANGER Immediately imminent danger Failure to observe the information will result in death or severe injuries WARNING Possibly imminent danger Failure to observe the information may result in death or severe injuries CAUTION Dangerous situation Failure to observe the information may result in minor or severe injuries as well as...

Страница 5: ...erfect condition Always observe the operating instructions all pertinent local and na tional directives and guidelines as well as the applicable safety regulations and directives concerning the prevention of acci dents Unimes E is not safety equipment It does not replace the func tion of a level sensor at the fuel oil tank Unimes E may only be installed in unpressurised tanks An ap proved tank ven...

Страница 6: ...O INDEX GmbH spare parts and accessories refer to chapter 11 page 19 2 7 Liability information AFRISO EURO INDEX GmbH shall not be liable in any form whatsoever for damages and consequential damages resulting from failure to observe the technical instructions guidelines and recommendations The manufacturer or the sales company shall not be liable for costs or damages incurred by the user or by thi...

Страница 7: ... delivery Direct indication gauge with float 1 Direct indication gauge 2 G2 thread 3 G1 thread 4 Float Remote indicator with battery and connection cable 1 Display 2 Programming keys 3 PG cable gland 4 Connection cable 5 Function key Wall bracket for remote indicator ...

Страница 8: ... means of a long lasting battery It is only switched on to read the level push to read function Diverse tank shapes are stored in a microprocessor so that the level is indicated either in liq uid level or volume as desired This combination of devices allows you to check the supply directly next to the tank and from an easily accessible different location The measurement signal is transmitted to th...

Страница 9: ...ange Medium 0 C to 60 C Storage 5 C to 80 C Electrical safety Protection IP 30 EN 60529 Table 2 Float Parameter Value Housing dimensions ø x H 42 x 100 mm Weight 95 g Housing material PE HD Table 3 Remote indicator Parameter Value General specifications Dimensions ø x D 75 x 50 mm Weight 380 g Cable length 10 m Housing material PA6 15 glass loaded Supply 3 6 V lithium battery Service life of batte...

Страница 10: ...0082 1 Accuracy of the complete system 5 FSO IEC 60770 relating to indication of the liquid level in mm 4 1 Approvals tests conformities Unimes E complies with the EMC directive 89 336 EEC und 92 31 EEC 5 Transport and storage CAUTION Damage to the device due to improper transport Do not throw or drop the device CAUTION Damage to the device due to improper storage Protect the device from shock whe...

Страница 11: ... other linear measuring applications 2 Cylindrical tank Vertically mounted cylinders 3 Ball shaped tank Tanks with the shape of a ball 4 Plastic battery type tank Plastic battery type tanks with straps or bulges 5 Oval tank Oval basement tanks e g glass fibre re enforced tanks or sheet metal tanks 6 Plastic tank with recess Plastic tanks with larger recesses in the tank centre manufacturers e g Ro...

Страница 12: ...ls 1 Lead seal 1 fixated 2 Lead seal 2 fixated 3 Lead seal 3 moving Fig 2 Float wire Tank without manhole or flange connection piece Push the float up to lead seal 2 and press lead seal 3 together to fixate the float Tank with manhole or flange connection piece 1 Deduct the excess length of the manhole or the flange connec tion piece with reference top the wire length from probe 2 to wards probe 1...

Страница 13: ...ointer to zero The direct indication gauge is now adjusted to the tank 6 5 Connecting the direct indication gauge and the remote indi cator Plug the connector of the connection cable into the rear side of the direct indication gauge 6 6 Connecting the battery of the remote indicator 1 When the direct indication gauge and the remote indicator are electrically connected open the housing of the remot...

Страница 14: ...e the housing of the remote indicator by pushing the hous ing parts together The remote indicator was switched on when the battery was con nected The display toggles between Zero and the current offset of the complete system The upper left corner of the display shows the two arrows to indicate that the instrument is in calibration mode 2 Press the two keys and simultaneously in order to correct th...

Страница 15: ...been entered 1 Use the and keys to enter the total volume of the tank fa cility By pressing the key you can select the digit to be changed The key allows you to change the selected digit within a range from 0 to 9 2 Up to a volume of 9999 litres the volume is entered in litres without decimal places In the case of volumes of 9999 litres the value is entered in cubic metres with a decimal place 100...

Страница 16: ...ave now entered all the tank data and the remote indicator switches to normal measurement mode The symbol in the upper left corner of the display is no longer shown 6 9 Mounting the direct indication gauge 1 Slowly lower the float into the tank 2 Screw the direct indication gauge into the tank 7 Operation 7 1 Switching Unimes E on and off Direct indication gauge The direct indication gauge is alwa...

Страница 17: ...ank data the display starts to flash The display toggles be tween the displayed value and Only the current liquid level in mm is displayed permanently 1 Hold down the keys simultaneously for 3 seconds to acti vate the Enter Tank Data mode The upper left corner of the display shows the symbol 2 The individual tank data can be checked and or overwritten as described in chapter 6 1 page 11 If you do ...

Страница 18: ... is replaced 9 Troubleshooting Repairs may only be performed by specially trained qualified staff Table 4 Troubleshooting Problem Possible reason Repair OFF is shown on the display of the remote indicator Automatic shut down after 2 minutes Press F key to read the liquid level is shown on the display of the re mote indicator Battery voltage below critical value Replace battery refer to chapter 8 2...

Страница 19: ...disposal 1 Dismount the device see chapter 6 page 11 reverse sequence of steps 2 To protect the environment this device must not be disposed of together with the normal household waste Dispose of the de vice according to the local conditions and directives This device consists of materials that can be reused by recycling firms The electronic inserts can be easily separated and the device consists ...

Страница 20: ... be reprinted translated copied in part or in whole with the prior written consent of AFRISO EURO INDEX GmbH We reserve the right to technical modifications with reference to the specifications and illustrations in this manual 14 Customer satisfaction Customer satisfaction is the prime objective of AFRISO EURO INDEX GmbH Please get in touch with us if you have any ques tions suggestions or problem...