![Afriso EURO-INDEX D0 Скачать руководство пользователя страница 40](http://html1.mh-extra.com/html/afriso-euro-index/d0/d0_operating-instructions-manual_2864879040.webp)
Decommissioning, disposal
40
Bourdon tube, capsule, diaphragm, spring diaphragm pressure gauges
12 Decommissioning, disposal
1.
Liquid filled pressure gauges: Remove the plug at the edge of
the housing and completely empty the pressure gauge (drip-
free).
Usually, Bourdon tube pressure gauges and capsule pressure gaug-
es are glycerine-filled (99.5 %), the spring diaphragm pressure
gauges are filled with a glycerine/water mixture (66 %). Pressure
gauges with glycerine filling do not have special marks. If other liq-
uids are used, a corresponding note providing information on the fill-
ing liquid is attached to the pressure gauge.
Table 15: Filling liquids for liquid filled pressure gauges
Filling liquid
European Waste Catalogue
(EWC) code no.
Glycerine (99.5 %)
13 02 08
Glycerine/water (86,5%/66 %)
13 02 08
Silicone oil
13 02 08
Paraffin oil
13 02 08
Glissofluid A9
13 02 08
2.
To protect the environment, filling liquid must
neither
be dis-
posed of together with the normal household waste
nor
get into
waters or the public drain system. Observe all applicable regula-
tions when disposing of it. Have authorised specialised compa-
nies collect and dispose of the filling liquid.
3.
Dismount the product (see chapter 7, page 21, reverse se-
quence of steps).
4.
To protect the environment, this product must
not
be disposed
of together with the normal household waste. Dispose of the
product according to according to local directives and guide-
lines.
This product consists of materials that can be reused by recycling
firms. The electronic inserts can be easily separated and the device
consists of recyclable materials.
If you do not have the opportunity to dispose of the used device in
accordance with environmental regulations, please contact us for
possibilities to return it (see chapter 12, page 40).