Maintenance 61
4510012 - REV F – 220621
Checking and Cleaning the Probes
Every 3 months, check and clean the Probes that check the water level inside the Boiler.
NOTE:
Only two of the three Probes are used. The third Probe is included as a spare, which
can be cut to match the length of the Probe that it is replacing. However, all three Probes
should be cleaned during the maintenance procedure described below.
Needed to Clean the Probes:
•
3/16” Crescent Wrench
•
20mm Socket Wrench
•
Scotch Brite™ Pads
•
Plumber’s Tape
To Clean the Probes:
The three Probes are located on the top of the Boiler Tank. Using the 3/16” Crescent
Wrench, disconnect the Wires from the top of each Probe, making note of which wire
connects to which Probe.
Using the 20mm Socket Wrench, loosen the Nut that holds each Probe in place and pull
each Probe upward to remove it from the Boiler Tank.
Clean lower
brass rod with
Scotch Brite pads
Disconnect
Wires
Remove old
Plumber’s Tape
from Threads,
replace with new
Plumber’s Tape
Содержание STC-WSN300-2M
Страница 1: ...WSN GEN S Steam Heat Shrink Tunnel User Guide ...
Страница 2: ...2 Abbreviations 4510012 REV F 220621 ...
Страница 8: ...8 Abbreviations 4510012 REV F 220621 ...
Страница 28: ...28 Introduction 4510012 REV F 220621 STC WSN600 2M GEN S Top View Front View Exit View Entry View ...
Страница 66: ...66 Troubleshooting 4510012 REV F 220621 ...
Страница 67: ...Electrical Schematics 67 4510012 REV F 220621 Electrical Schematics Complete System WSN GEN S ...
Страница 68: ...68 Electrical Schematics 4510012 REV F 220621 Boiler ...
Страница 72: ...72 Parts List 4510012 REV F 220621 Exploded Diagrams Stand Drawing Number YS130EX2 01 ...
Страница 74: ...74 Parts List 4510012 REV F 220621 Tunnel Drawing Number YS130EX2 02 ...
Страница 78: ...78 Parts List 4510012 REV F 220621 Boiler ...
Страница 79: ...Parts List 79 4510012 REV F 220621 Inside Boiler Electrical Cabinet ...
Страница 84: ...84 Technical Support 4510012 REV F 220621 ...