Troubleshooting 57
In
Registration
mode,
the label cut
position is
inconsistent
Check that the Film Feed Rollers are not skidding on the
label (i.e. Film Feed Rollers not tight enough); verify that the
label material is not getting jammed or impeded above the
Film Feed Rollers; check for lint or dirt between the fibers of
the
print registration
eye; also check the
eye-mark
of the
label to make sure that the opaque~transparent transition is
not “cloudy” (this would be a materials problem); you can
narrow the cause down by running the machine in FIXED
CUT mode to see if the behavior changes
Application Fail
fault keeps
occurring even
though there is
no label jam
Increase the value of the Application Fail TIMER and run the
machine again; check the position and adjustment of the
Application Fail
photo-eye – the LED should light only when
there is a label just below the Mandrel (the amplifier for the
eye is located beneath the left-hand side cover of the
LX-150).
*correct
Application Fail
photo-eye position is between
base of Mandrel and cap of container
Timing Screw is
starting and
stopping erratically
Verify that Infeed Low and Discharge Low photo-eyes are
not contaminated with dust or condensation
Label is splitting
along the
crease
Check the UR2 Reel Assemblies and Dancer and LX-150
Dancer and Mandrel Fin for burrs which may be damaging
the label; also, film rewind tension may be too high
(defective labels)
Label is splitting
along the
seam
This is most likely a label materials problem – insufficient
solvent on the seam – change to a different roll of labels
Film is twisting on
Mandrel
Create more back-tension by slowing the Inner Dancer
motor
A servo motor
constantly
generates an Error
Message
Most likely cause is mechanical binding (e.g. Perforator:
perforations may be too deep; Cutter: label material may
have accumulated in the Cutter unit; Film Feed: label may
be getting caught above the Mandrel
A VFD constantly
generates a
fault and shuts
down,
requiring a
reset
of
the VFD
Most likely cause is mechanical binding (e.g. Inner Dancer
VFD: film jam in Dancer)
Содержание LX-100
Страница 1: ...Shrink Sleeve Label Applicator Model Number LX 100 User Guide ...
Страница 2: ......
Страница 4: ......
Страница 7: ...Safety 7 ...
Страница 35: ...Operation 35 Typical setup 2107 Heat Tunnel LX 100 TTO Timing Screw not shown Brush down Not shown Conveyor ...
Страница 45: ...Operation 45 Screen 13 X 1951 CUT LENGTH mm Jump to Screen 30 Press here to access keyboard ...
Страница 60: ...60 Print Reading Sensor Print Reading Sensor details 1406 ...
Страница 77: ...Schematic Diagrams 77 ...
Страница 96: ......
Страница 97: ......
Страница 98: ......