Operation 41
6. Repeat step 4 of above to check where the labels are being cut after you have
entered the offset length.
7. If the label's actual cutting location is below the location of the planned cut, then the
offset length should be increased.
** If the label's actual cutting location is above the location of the planned cut, the offset
length should be decreased.
8.Turn on the work switch.
9.Test run with the actual objects being sleeved, adjust the work detect sensor's
position to shoot the labels onto each bottle accurately.
** If the label falls too soon, before the bottle is underneath the center line of the
mandrel, move the sensor towards the mandrel (as shown in Picture 1).
** If the label falls too late, after the bottle has passed underneath the center line of the
mandrel, move the sensor away from the mandrel (as shown in Picture 2).
1387
Picture 1
Picture 2