AFL U-Series 3RU Скачать руководство пользователя страница 1

Installation Guide

3RU Splice and 
Patch Panel

Series

Содержание U-Series 3RU

Страница 1: ...Installation Guide 3RU Splice and Patch Panel Series ...

Страница 2: ...for an eye examination immediately General Precautions Personnel must be thoroughly familiarized with all applicable Occupational Health and Safety OH S regulations local regulations and your company safety practices and policies Warning To reduce the chance of accidental injury Before work begins all personnel must be thoroughly familiar with the operation of all equipment and procedures to be us...

Страница 3: ...3 U Series 3RU Splice and Patch Panel AFL Hyperscale All rights reserved Series Component Overview 01 02 07 06 05 04 03 ...

Страница 4: ...ngth of Ø32mm Conduit 1 1 12 Ribbon Pigtail 12 12 13 Hose Clip Ø11 16mm 2 2 01 U Series 3RU Splice and Patch Panel 04 Brush Strip Cross Head Flat Head Screwdriver 07 Front Door Assembly 10 Cable Tie Black 300mm x 4 5mm 02 U Series Patch Adapter Plate 05 Rear Cover 08 M6 Cage Nut Screw 11 500mm Length of Ø32mm Conduit 13 Hose Clip Ø11 16mm 03 Patch Cable Management 06 Internal Fiber Slack Managemen...

Страница 5: ...n Procedure Turn the quick release fasteners anti clockwise to remove the rear cover 05 4 Attach the front door assembly 07 as shown 3 Insert the cage nut screws 08 with a screwdriver 2 Insert cage nuts 08 in the positions shown above on both the left and right hand sides of the rack 1 3U 2U ...

Страница 6: ...able tie 10 the conduit to the bracket 7 Remove the brush strip 14 tie off the cable using the hose clip 13 and flat head screwdriver ensure the jacket strip point is as shown 6 Installation Procedure Slide the hose clip 13 and conduit 11 cut to 150mm over the cable and strip 1m of cable jacket in accordance with the cable manufacturers guidelines 5 1m approx 150mm approx Jacket strip point ...

Страница 7: ...f the fasteners they will click when they are closed 12 Re dress the fiber into the panel clipping the splice protectors into the holders Use the dotted line route for re spliced fibers 11 Undress the fiber from all the managers and splice according to splice schedule and cable manufacturers guidelines approx 700mm of slack available 10 Dress the fiber into the panel as per the green route cut bot...

Страница 8: ...10 Purple 11 Pink 12 Aqua Position Number Fiber Tubing Color 13 Orange 14 Blue 15 Brown 16 Green 17 White 18 Grey 19 Black 20 Red 21 Purple 22 Yellow 23 Aqua 24 Pink 1 2 3 4 5 6 7 8 9 10 11 12 Adapter Plate Numbers Adapter Plate Numbers Adapter Keyway Up Position Number 1 3 5 7 9 11 2 Position Number 4 6 8 10 12 Position Number Fiber Tubing Color 1 Blue 2 Orange 3 Green 4 Brown 5 Grey 6 White 7 Re...

Страница 9: ...9 U Series 3RU Splice and Patch Panel AFL Hyperscale All rights reserved Series Notes ...

Страница 10: ...10 AFL Hyperscale All rights reserved Series Notes ...

Страница 11: ...11 U Series 3RU Splice and Patch Panel AFL Hyperscale All rights reserved Series Notes ...

Страница 12: ...Thank you for choosing AFL Hyperscale AFLHS3RUSPP270820 www aflhyperscale com AFL Hyperscale reserves the right to make changes in this Installation Guide at any time without notice ...