Affymetrix DMET Plus Array Скачать руководство пользователя страница 1

ARRAYS

INTENDED USE

Human genome sequence variation, which includes both single nucleotide 
polymorphisms (SNPs) as well as more complex structural variation in the form 
of insertions, duplications and deletions, underlies each individual’s response to 
drugs. The DMET™ Plus Array is part of the DMET™ (Drug-Metabolizing 
Enzymes and Transporters) Plus Premier Pack that enables comprehensive and 
accurate genotyping of specifi c polymorphisms involved in drug metabolism 
response.

The polymorphisms represented on this array were chosen by virtue of their 

functional signifi cance as documented in the scientifi c literature and have been 
publicly reviewed and prioritized by a panel of experts made up from both 
the pharmaceutical industry and academia. The product is capable of genotyp-
ing 1,936 high-value drug metabolism and transporter markers in 225 genes. 
These markers have been evaluated across a minimum of 1,200 individuals 
from multiple populations, including Caucasian, African and Asian.

Refer to the 

DMET

 Plus User Guide

 (P/N 702687) for procedures on DNA 

target preparation, target hybridization, fl uidics setup, and array scanning for 
processing DMET Plus Arrays.

SPECIFICATIONS

Specification

Value

Array Format

169

Feature Size

5 µm

Fluidics Station Protocol

DMET_Plus_169_v2

Hybridization Volume

95  µL

Library Files

DMET_Plus*.*

ORDERING INFORMATION

P/N

Product Name

Description

901317

DMET Plus Array 

48 Arrays

Affymetrix

®

 products can be purchased directly from Affymetrix in the 

United States, and many European and Asian countries. For all other terri-
tories, please view a list of our distribution partners, which can be located at 
www.affymetrix.com/site/contact/index.affx.

INSTRUMENTATION AND SOFTWARE REQUIRED

1.

 Affymetrix GeneChip

®

 Scanner 3000

2.

 Affymetrix GeneChip

®

 Fluidics Station 450

3.

 Affymetrix GeneChip

®

 Command Console (AGCC)

4.

 Affymetrix GeneChip

® 

Hybridization Oven 640 or 645

STORAGE, HANDLING AND STABILITY

The DMET Plus Array consists of a square glass substrate mounted in a plastic 
cartridge (Figure 1). The glass contains an array of oligonucleotides that, when 
mounted, is on the inner glass surface. A chamber in the plastic housing direct-
ly under the glass acts as a reservoir where hybridization and washing occur.

Although the inner glass surface of the probe array is protected, any con-

tamination or scratches on the outer surface of the glass can compromise the 
accuracy of the scan. Avoid touching the surface of the glass with your fi ngers. 
Skin oils and other substances, such as lotions or ink, can fl uoresce. If the surface 
of the glass is noticeably dirty, it can be carefully cleaned with a non-abrasive 

laboratory tissue.

Figure 1.  DMET Plus Array

DMET Plus

 

Arrays should be stored at 2° to 8°C. Refer to the expiration date 

on the package label. Do not use arrays or reagents after the expiration date.

PRECAUTIONS

1.

  DMET PLUS ARRAYS ARE FOR RESEARCH USE ONLY; NOT FOR 

DIAGNOSTIC PROCEDURES.

2.

  Avoid microbial contamination, which may cause erroneous results.

3.

 

WARNING: All biological specimens and materials with which they 
come into contact should be handled as if capable of transmitting 
infection and disposed of with proper precautions in accordance 
with federal, state, and local regulations. This includes adherence to 
the OSHA Bloodborne Pathogens Standard (29 CFR 1910.1030) for 
blood-derived and other samples governed by this act. Never pipet by 
mouth. Avoid specimen contact with skin and mucous membranes.

4.

 

CAUTION:

 Exercise standard precautions when obtaining, handling, and 

disposing of potentially carcinogenic reagents.

5.

  Exercise care to avoid cross-contamination of samples during all steps of this 

procedure, as this may lead to erroneous results.

6.

  Use powder-free gloves whenever possible to minimize introduction of pow-

der particles into sample or probe array cartridges.

DMET™ Plus Array