Troubleshooting Guide
AF 950001-B • 633 Compact Fogger
Problem
Possible Cause / Solution
Startup
Maintenance
A) Fogger will not draw chemical or is sputtering
B) Fog is too wet
1, 2, 3, 4
1, 4
6, 7, 8
5
Possible Cause / Solution
Startup
Maintenance
1.
Air line too small, not enough air pressure or volume
See REQUIREMENTS, page 1.
2.
Air pressure too high.
Slightly close the air supply valve to lower the pressure by
lowering the volume till the fogger smooths out.
3.
Chemical tube kinked or not immersed in chemical or chemical
depleted.
Straighten tube / replenish chemical
4.
Drawing too much solution
Install optional metering tip
5.
Pin hole or cut in suction tube
Replace suction tube.
6.
Chemical tube clogged up
Clean or replace
7.
Metering tip or metering tip holder clogged
Clean or replace metering tip and/or metering tip holder.
8.
Debris clogging the fogger inlet jets
Disconnect air supply, remove fogger bodies and visually inspect;
remove debris from fogger inlet.
PREVENTIVE MAINTENANCE: When the unit will be out of service for extended periods, place chemical tube(s) in water and flush
the chemical out of the unit to help prevent chemical from drying out and causing build-up. Periodically check and clean chemical
strainer and replace if missing.
Printed: Thursday Jun 26th 2014
- Page 4 -
Содержание AF 950001-B
Страница 3: ...AF 950001 B 633 Compact Fogger Page 3 ...