5.3 Status
The “Status” tool displays the actual status of the device (target
values, actual values, limits, I/O status and MPU status).
Comment: As the units vary and are very extensive depending on
the corresponding application they are not
displayed in the “Status”
tool. The units displayed here are current default units. The
deviations are however specified in the following descriptions.
Please pay attention to the indications for the corresponding
objects.
Device informations
Max. power voltage
Maximum voltage which may be applied to the power voltage input
of the SE-24 servo controller. Power supply connector X1, pin 3.
Max. motor current
Maximum current that can be supplied from the SE-24 servo
controller to a motor.
Nominal
electronic
voltage Ue
Nominal voltage of the controller electronics. This voltage is
applied to pin 2 of the power supply connector X2.
Actual supply voltage
Uelectronics (Ue)
Current actual voltage for the electronics which is applied to pin 2
of the power supply connector X1.
Upower (Up)
Current actual voltage for the power which is applied to pin 3 of the
power supply connector X1.