Page 20
12/02/2020
R05.1
5.3
Replacing the magnetic coil
This procedure is only necessary when:
-
The magnetic coil is defective
WARNING
Unplug the power cable, before proceeding with further actions!
1.
Loosen the screws (1) on the oscillation plate (2) and remove the entire unit
2.
Unplug the Euro plug from the control unit and disassemble
WARNING
Electrical work must only be carried out by trained personnel!
3.
Remove the screws (5) from the distance plate (6), if installed and remove the dis-
tance plate from the support base (7) by loosening the screws (8)
4.
Loosen the cable clamp (9) and remove the screws (10). Remove the magnetic
coil (11) and pull the cable through the cable clamp.
5.
Reassemble in the reverse order.
NOTE
This procedure generally includes adjustment of the air gap be-
tween the magnetic coil and the anchor bolt.
(See chapter 5.4).