Installation, assembly & setting
Assembly instructions EN
GE-25-P
Date 02.11.2021
Version 1.0
31–48
6.4 Electrical connection
6.4.1 Digital I/O variant
Power supply and control
Fig. 8
M8 connector for gripper (view to connector)
Pin
Strand
Signal
1
Brown
+ 24 V
2
White
Open gripper
3
blue
GND
4
Black
Close gripper
Pin assignment
Connection Plug connector EBP Connector (customer)
Gripper
Connector 4-pole, M8 Connection cable 4-pole, socket M8
Components electrical connection
Tightening torque M8 plug-in connection:
50 cNm.
WARNING
Danger due to electrostatic energy!
Components or assemblies can become electrostatically charged. When
touched, the electrostatic discharge can cause a startle reaction that can lead
to injuries
.
The operator must ensure that all components and assemblies are included
in the local equipotential bonding in accordance with the relevant rules.
Have the equipotential bonding carried out by a qualified electrician in
accordance with the relevant rules, taking particular account of the actual
working environment conditions.
Have the effectiveness of the equipotential bonding verified by regular
safety measurements.