Operating instructions EN
◼
SE-24
◼
01.06.2022
◼
V1.5
37
–66
7.1.8 CANopen connection
The CANopen connection on the SE-24 servo controller is carried out as a 5 pole M12
plug or socket (a-coded).
7.1.8.1 CANopen IN [X2a]
Figure 10: View of the connection [X2a]
7.1.8.2 CANopen OUT [X3a]
Figure 11: View of the connection [X3a]
For the functional description of the input and output data please see the document:
SE-24 CANopen Manual
X2a, CANopen IN
Flush-type plug, 5 pole M12, a-coded
Phoenix: 1419645
SACC-DSI-M12MS-5CON-M16/0,5
Pin
Designation
Specification
1
Shield
2
n.c.
3
CAN_GND
Data ground
4
CAN_H
CAN high
5
CAN_L
CAN low
X3a, CANopen OUT
Flush-type socket, 5 pole M12, a-coded
Phoenix: 1419658
SACC-DSI-M12FS-5CON-M16/0,5
Pin
Designation
Specification
1
Shield
2
n.c.
3
CAN_GND
Data ground
4
CAN_H
CAN high
5
CAN_L
CAN low