![Afag 50315434 Скачать руководство пользователя страница 30](http://html.mh-extra.com/html/afag/50315434/50315434_operating-instructions-manual_2864001030.webp)
30
– 66
Operating instructions EN
◼
SE-24
◼
01.06.2022
◼
V1.5
7.1.1 Power supply connection [X1]
Figure 4: View of the connection [X1]
7.1.1.1 Type on device [X1]
▪
Intercontec, 4 pole M17; flush-type power plug; BEGA894MR0900153A000
7.1.1.2 Mating plug [X1]
▪
Power cable SE-24/SE-48, 5 m, Afag no. 50118124
7.1.1.3 Pin assignment [X1]
Pin
No.
Designation
Specification
1
0 Volt
Common ground potential for the 24 V power
supply and the 24 V control supply
Conductor cross-section at least 1.5mm
2
2
U
e
24 Volt
Voltage supply of the control electronics
Conductor cross-section at least 1.0mm
2
3
U
p
24 Volt
Voltage supply of the power electronics
Conductor cross-section at least 1.5mm
2
PE
PE
Connection to housing
CAUTION
Do not mix up the voltage supply lines.
The complete motor connection is designed for poled DC voltage.
Mixing up the plus and the minus pole will lead to severe damage to
the electronics.