Mounting Instructions EN
◼
SE-Power FS
◼
01.06.2022
◼
V4.4
19
–50
3
Technical data
Table 1:
Technical data: Ambient conditions and qualification
Range
Values
Admissible temperature ranges
Storage temperature: -25°C to +70°C
Operating
temperature:
0°C to +40°C
+40°C to +50°C at reduced
power 2,5% /K
Admissible installation height
Up to 1000 m above msl, 1000 to 2000 m above msl at
reduced power according to EN 61800-5-1
Humidity
Relative humidity up to 90 %, not bedewing
Protection class
IP20
Pollution degree
1
CE conformity
Low-voltage directive
:
EMC regulation:
Current harmonics:
EN 60 800
– 5 - 1
EN 61 800 - 3
EN 61 000 - 3
– 2
Further certifications
UL
certified
Table 2:
Technical data: Dimensions and weight
Type
SE-Power FS 1kVA
SE-Power FS
3kVA
SE-Power FS
6kVA
Dimensions including the
mounting plate (H*W*D)
261mm*54,5mm*205mm
334,5mm*69mm*245,5mm
Dimensions (H*W*D)
200mm*54mm*200mm
250mm*69mm*240mm
Weight
approx. 2,1kg
approx. 3,7kg
Table 3:
Technical data: Cable specifications
Range
SE-Power
FS 1kVA
SE-Power
FS 3kVA
SE-Power
FS 6kVA
Maximum motor cable length for interference emission as per EN 61800-3
Category C2
Switch cabinet assembly (see chapter
l
25m
l
50m
Category
C3
(industrial area)
l
25m
l
50m
Cable capacity of a phase against shield or
between two lines
C‘
200pF/m