AES 7094A IntelliPro Скачать руководство пользователя страница 1

Out of the Box 

1. IntelliPro Module (1) 

AES Part# 72-7094A 

2. RJ11 Cable (1) 

  

AES Part# 13-0395 

3. Kepnuts (4) 

 

AES Part# 09-1006 

4. Insulating washer (2) 

AES Part# 09-7X94 

 

Overview 

The 7094A full data module is an alarm reporting interface for the AES 
Model 7007 Security Subscriber Unit. The 7094A is UL listed for use in 
Commercial Security Installations with or without a phone line. This 
document describes installation of AES Model 7007 subscriber with the 
interface to an Alarm Panel (AP) via the AP dialer interface. The 7094A 
decodes a CID, PULSE, Modem II, or a Modem III message received on its 
AP phone interface and sends the message via the AES subscriber radio. 
The 7094A also provides a full replacement to a POTS line as well as POTS 
monitoring when POTS is present. 

User Interface 

A web browser and network connection to the Model 7007 subscriber is 
required to program the 7094A. The 7094A has one STATUS LED to 
indicate operation and heartbeat. 

 

Installation 

1.

 

Be sure primary and battery backup power to the subscriber are 
disconnected. 

2.

 

Remove the four (4) lower hex nuts holding the main board inside 
the 7007 enclosure. Save the nuts. 

3.

 

Mount the 7094A board on standoffs, and secure with 4 kepnuts 
(provided with 7094A). 

4.

 

Install insulating washer (provided with 7094A) over H1 (upper left 
corner) H3 (lower left corner). 

5.

 

Secure the 7094A with the 4 nuts removed in Step 1 above. 

6.

 

Install the 6 wire modular cord (provided) between 7094A J1 and 
7007 subscriber connector J7 ARM. Power up the subscriber. 

LIMITED PRODUCT WARRANTY:

 

AES warrants to the original purchaser 

that the AES Subscriber Unit will be free from defects in material and workmanship 
under normal use and service for three (3) years from the date of original 
purchaser’s purchase.  Except as required by law, this Limited Warranty is only 
made to the original purchaser and may not be transferred to any third party. This 
Limited Product Warranty is made in lieu of any other warranties, expressed or 
implied, it being understood that all other warranties, expressed or implied, 
including of merchantability or fitness for a particular purpose, are hereby 
expressly excluded. AES assumes no liability for any personal injury, property 
damage, consequential damages, or any other loss or damage due, among other 
things, to this product’s failure to operate or provide adequate warning. AES’s sole 
responsibility is to repair or replace, at AES’s sole option, the AES product that is 
judged defected by AES during the limited warranty period under the terms of its 
Limited Warranty.

 

Firmware Version 

The firmware version is displayed in the web browser Status page  

under the Hardware–Panel Interface
 

7094A Configuration 

 
Select the Accessories page. Use controls in the IntelliPro panel to  
set parameters. 

Item 

Parameter 

Default value 

Phone line 

No 

Intercept Number 

555 

AP Report Format 

CID 

AP input gain 

20 

Intercept on blind dial 

No 

Line Cut Report 

Yes 

POTS Cut Report Delay 

45 sec 

POTS Restoral Delay 

60 sec 

AP ACCT Override 

No 

10 

POTS Input Gain 

20 

11 

Advanced Options Display 

No 

12 

AP Output gain 

13 

Reset to defaults 

14 

Line-cut sensing Enabled 

Yes 

15 

CID 4xx Letter 

16 

M3 EC TEXT to CID 

Yes 

17 

Voltage Pump Enabled 

Yes 

18 

Clock Freq. Shift Enabled 

No 

 
CONFIGURATION SETTINGS
 

 

Phone line:  YES or NO for POTS line presence. 

 

Intercept Number: Enter a phone number such as 555. 

 

AP report format:  CID, MODEM and PULSE depending on Alarm 
Panel. 

FOR MODEM SELECTION 

AP MODEM format: Set to MODEM2 or MODEM3.  If you select 
MODEM3 format, set Advanced Options to YES to set M3 Text to CID. 

This table shows panel models tested and the MODEM format supported.  

Panel Model 

Revision Number 

Format Tested 

D7412GV2  

7.08 

Modem III 

D7412GV3   

8.03 

Modem III 

D8112E1/G1  

22 

Pulse Only 

D8112G2   

31.31 

Modem II 

D6112  

4.0 

Modem II 

D2212B   

3.03 (IIe = III)  

Modem III 

D4412 

1.12 

Modem III 

D9412G 

6.6 

Modem III 

 

 

FOR PULSE SELECTION 

Parameter 

Default value 

Available values 

Handshake Duration (HSD) 

0.8 sec 

0.8, 0.4 

Handshake Frequency (HSF) 

1.4 KHz 

1.4, 2.3 

Center Frequency (CF) 

1.8 KHz 

1.8, 1.9 

Inter-Digit Time (IDT) 

0.7 sec 

0.7, 0.9, 1.7 

Inter-Round Time (IRT) 

3.0 sec 

3.0, 5.0 

 

 
 
 

  

 Quick Start Guide 

AES Model 7094A IntelliPro 

            

Page 1 of 2 

 

  AES Corporation 

To view the complete Installation Manual, refer to website: 

http://aes-corp.com

 

 

40-7094A-QSG  Rev. 4 4/15/2019 