B
u
tt
o
n
1
B
u
tt
o
n
2
B
u
tt
o
n
3
B
u
tt
o
n
4
C
C
C
C
+
-
+24V-
+
-
101
220
R
EL
A
Y
2
R
EL
A
Y
1
1
2
3
4
C
12V
OUT
24V
AC DC
IN
RELAY
1
RELAY
2
+
-
N/ C
| C |
N/ O
N/ O
| C |
N/ C
= COMMON
N/ O
C
N/ C
Link both Relay 1’s to
allow either to release the
same door / gate.
N/ C
| C |
N/ O
N/ O
| C |
N/ C
SITE SURVEY
OPTIMAL RANGE
WIRING DIAGRAM
TIP:
For longer range installations, locate the handset closest to the front of the
property and near a window if possible. Also ensure the transmitter is mounted
pointing towards the handset.
Concrete walls can reduce the normal open-air range of up to 400 metres/yards
by
30-50% per wall
.
TIP:
Most technical calls received are due to installers using CAT5 or alarm cable
to power the unit.
NEITHER
are rated to carry enough power!
( 1.2amp peak )
Please use the following cable:
Up to 2 metres ( 6 feet )
–
Use minimum
0.5mm
2
( 18 gauge )
Up to 4 metres ( 12 feet )
–
Use minimum
0.75mm
2
( 16 gauge )
Up to 8 metres ( 24 feet )
–
Use minimum
1.0mm
2
( 14 / 16 gauge )
POWER CABLE
Shield/Filter
Drain Cable
Insert Drain Cable into
0v (-) on Power IN
Code
Button
Optional
Antenna
Pairing
LEDs
Normally Open
Common
Normally Closed
RELAY CONNECTIONS
RELAY 1
RELAY 1
Transmitter Module
WARNING:
ESD SENSITIVE
To Gate Controller
24V AES Power Supply
* ALWAYS RANGE TEST THE UNIT ON SITE BEFORE INSTALLATION *
MAX 24 VOLTS!
POWER ADAPTER
MAINS
POWER
MAGNETIC LOCK
MAGNETIC LOCK EXAMPLE
TRANSMITTER
AES KEYPAD
+
-
-
+
* MAGNETIC LOCK PSU SOLD SEPARATELY *
Follow this method when using a magnetic lock. If the relay in either the
Transmitter or
optional AES Keypad
is triggered it will temporarily lose power
and allow the door/gate to release.
For installs without the
optional AES Keypad
; connect the
POSITIVE
of the
Magnetic Lock PSU to
N/C
terminal on Transmitter Relay.
NEED MORE ASSISTANCE?
Please scan this QR Code to be
brought to our Resources page
where you can find all of our
guides and available resources.
EXIT
SUFFICIENT POWER CABLE FOR
CALLPOINT REQUIRED ( 2x1mm
2
)
LIGHTNING PRONE AREAS
MUST USE SURGE PROTECTION
FOR POWER SUPPLY!
703 DECT
- Imperial Intercom System
STILL HAVING TROUBLE?
Find all of our support options such as Web Chat,
Full Manuals, Customer Helpline and more on
our website:
WWW
.
AESGLOBALONLINE
.
COM
SYSTEM INCOMPATIBLE WITH FOIL INSULATION.
KEEP POWER SUPPLY AS CLOSE AS POSSIBLE.
KEEP SHORT
( 8m MAX! )
RESTOCKING FEES MAY APPLY IF RETURNED AFTER INSTALL DUE TO SITE
ISSUES. PLEASE SEE FULL T&C’S ON OUR WEBSITE.
COM
COM
BUTTON 3
BUTTON 2
BUTTON 1
BUTTON 4
NOTE:
Wiring method will
change depending on
amount of buttons on
faceplate.
See provided supplement guide for
more info.
RELAY 1
R2
24v IN
THE AES KEYPAD IS AN OPTIONAL EXTRA.
IF KEYPAD PRESENT, PLEASE SEE ‘
KPX1200 GUIDE
’
FOR FULL INSTRUCTIONS ON PROGRAMMING AND
EXTENSIVE FEATURES.
Optional Programmable Keypad
RELAY 1
R2
12
.000
24v IN
EGRESS
R
EL
A
Y
3
GROUND
+ -
N.C. COM
N.O. N.C. / N.O.
DA TA
I/O
EG
IN
N.
C.
CO
M
N.
O
.
K
o
r
A
O
/P
DU
O
U
T
D
O
O
R
S
E
N
S
(-
)
G
N
D
O
/P
1
IN
H
IB
.
IN
T
L
O
C
K
T
A
M
P
E
R
N
.C
.
With our 703 DECT audio system you can
add up to a max of
4 portable handsets
or
wall mounted versions.
(1 DEVICE WILL RING PER BUTTON)
Did you know?
AES KP will come pre-
wired to the CallPoint
TIP:
It is recommended that the system be fully tested on site
BEFORE
installation.
You must test to ensure that the system is capable of operating across the desired
range. Power the system on and place the handsets in their expected locations
around the property to ensure that the system is fully functional and suitable for
the site.