2.1.2. Motor Supply Connector
IMPORTANT
: To operate correctly, this product must have a power supply connected
to the Motor Supply and a power supply connected to the Control Supply.
Motor power is applied to the XL4s at the four terminals of the Motor Supply connector. The DC+
input and the DC- input are connected to fuses inside the drive. Refer to
for fuse values
and part numbers.
IMPORTANT
: Refer to local electrical safety requirements to correctly size external
system wires.
DANGER
: To prevent the risk of electric shock, do not operate the XL4s without a
ground connection.
Figure 2-2:
Motor Supply Connections
Table 2-3:
Motor Supply Wiring Specifications
Pin
Description
Recommended
Wire Size
(1)
DC+
+40 VDC Input Range
2.1 mm
2
(#14 AWG)
RET
Return for DC Input
2.1 mm
2
(#14 AWG)
DC-
-40 VDC Input Range
2.1 mm
2
(#14 AWG)
Protective Ground
2.1 mm
2
(#14 AWG)
(1)The wire insulation is rated for 300 V.
Table 2-4:
Mating Connector Part Numbers for the Motor Supply Connector
Type
Aerotech
P/N
Third Part
P/N
Screw
Torque: N·m
Wire Size:
mm
2
[AWG]
4-Pin Terminal Block
ECK002407
Phoenix 1758843
0.5 - 0.6
3.3 - 0.0516 [12-30]
2.1.2. Motor Supply Connector
XL4s Hardware Manual
20
www.aerotech.com
Содержание XL4s
Страница 1: ...Revision 2 02 Automation1 XL4s High Performance Voice Coil Drive HARDWARE MANUAL...
Страница 6: ...This page intentionally left blank List of Tables XL4s Hardware Manual 6 www aerotech com...
Страница 17: ...1 2 2 Dimensions Figure 1 3 Dimensions XL4s Hardware Manual 1 2 2 Dimensions www aerotech com 17...
Страница 48: ...This page intentionally left blank Appendix B Revision History XL4s Hardware Manual 48 www aerotech com...
Страница 52: ...Index XL4s Hardware Manual This page intentionally left blank 52 www aerotech com...