2.5.6. Analog Output 0 (J205)
The analog output is set to zero when power is first applied to the system or during a system reset.
Table 2-33:
Analog Output 0 Specifications (TB102 B)
Specification
Value
Output Voltage
-10 V to +10 V
Output Current
5 mA
Resolution (bits)
16 bits
Resolution (volts)
305 µV
Table 2-34:
Analog Output Pins on the Auxiliary I/O Connector (J205)
Pin#
Description
In/Out/Bi
22
Analog Output 0
Output
23
Analog Common
-
Figure 2-32:
Analog Output 0 (J205)