2.10.4. STO Diagnostics
Activation of STO means removing power from the controller’s STO inputs. This is typically done by
pressing the emergency stop switch. The controller initiates a diagnostic check every time the STO is
activated after the Diagnostic Test Delay Time has elapsed. The diagnostic check verifies that each
channel has entered the safe state. The controller is held in the safe state if it determines that one of
the channels has not properly entered the safe state. An open circuit or short to 24 V in either
STO channel will result in this condition (refer to
). The Status Utility screen can be
used to verify the levels of the STO input signals while trouble shooting.
In order to meet the listed SIL level, the STO circuit must be activated (power removed from both
inputs) according to the interval specified in
.
Table 2-55:
STO Timing
Time Description
Value
T1
STO Delay Time (STO input active to motor power off)
450-550 msec
T2
STO deactivated to motor power on (the software is typically
configured so that the motor does not automatically re-
energize).
< 1 msec
T3
Diagnostic Test Delay Time
550-610 msec
Figure 2-48:
STO Timing
The software is typically configured to execute a controlled stop when the STO state is first detected.
If power is reapplied to the STO inputs before the STO Delay Time, an STO hardware shutdown will
not occur but a software stop may, depending on the width of the STO pulse. The controller will
ignore STO active pulses shorter in length than the STOPulseFilter parameter setting.
2.10.4. STO Diagnostics
iXR3/XR3 Hardware Manual
86
www.aerotech.com
Содержание Automation1 iXR3
Страница 1: ...Revision 2 08 Automation1 iXR3 and XR3 Drive Racks HARDWARE MANUAL...
Страница 16: ...Figure 1 2 XR3 Connection Overview Chapter 1 iXR3 XR3 Overview iXR3 XR3 Hardware Manual 16 www aerotech com...
Страница 97: ...Figure 3 3 Slot Details iXR3 XR3 Hardware Manual 3 3 Amplifier Replacement www aerotech com 97...
Страница 98: ...This page intentionally left blank 3 3 Amplifier Replacement iXR3 XR3 Hardware Manual 98 www aerotech com...
Страница 104: ...This page intentionally left blank Appendix C Revision History iXR3 XR3 Hardware Manual 104 www aerotech com...
Страница 111: ...W Warranty and Field Service 99 iXR3 XR3 Hardware Manual Index www aerotech com 111...
Страница 112: ...Index iXR3 XR3 Hardware Manual This page intentionally left blank 112 www aerotech com...