![Aerotech Automation1 iXC6e Скачать руководство пользователя страница 84](http://html1.mh-extra.com/html/aerotech/automation1-ixc6e/automation1-ixc6e_hardware-manual_2863025084.webp)
3.1. Digital Outputs [-EB1]
Optically-isolated solid-state relays drive the digital outputs. You can connect the digital outputs in
current sourcing or current sinking mode but you must connect all four outputs in a port in the same
configuration. Refer to
and
.
The digital outputs are not designed for high-voltage isolation applications and they should only be
used with ground-referenced circuits.
You must install suppression diodes on digital outputs that drive relays or other inductive devices. To
see an example of a current sourcing output that has diode suppression, refer to
. To see
an example of a current sinking output that has diode suppression, refer to
The digital outputs have overload protection. They will resume normal operation when the overload
is removed.
Table 3-1:
Digital Output Specifications [-EB1]
Digital Output Specifications
Value
Maximum Voltage
24 V (26 V Maximum)
Maximum Sink/Source Current
250 mA/output
Output Saturation Voltage
0.9 V at maximum current
Output Resistance
3.7 Ω
Rise / Fall Time
250 µs (2K pull up to 24V)
Reset State
Output Off (High Impedance State)
3.1. Digital Outputs [-EB1]
iXC6e/XC6e Hardware Manual
84
www.aerotech.com
Содержание Automation1 iXC6e
Страница 1: ...Revision 1 04 Automation1 iXC6e and XC6e High Powered PWM Digital Drives HARDWARE MANUAL...
Страница 63: ...Figure 2 28 PSO Interface iXC6e XC6e Hardware Manual 2 5 2 Position Synchronized Output PSO www aerotech com 63...
Страница 86: ...Figure 3 2 Digital Outputs Schematic EB1 3 1 Digital Outputs EB1 iXC6e XC6e Hardware Manual 86 www aerotech com...
Страница 104: ...This page intentionally left blank Appendix B Revision History iXC6e XC6e Hardware Manual 104 www aerotech com...
Страница 112: ...Index iXC6e XC6e Hardware Manual This page intentionally left blank 112 www aerotech com...