1.2. Mechanical Specifications
1.2.1. Mounting and Cooling
The drive must be installed in an enclosed control cabinet suitable for installation of power
equipment. A minimum enclosure rating of IP54 is required to comply with safety standards. Make
sure that there is sufficient clearance surrounding the drive for free airflow and for the routing of
cables and connections. Consideration for items such as line reactors, line filters, and motor chokes
or inductance should be made during the initial cabinet design phase.
Table 1-4:
Mounting Specifications
iXC6e/XC6e
Customer-Supplied Enclosure
IP54 Compliant
Weight
7 kg
Mounting Hardware
M4 [#8] screws (four locations, not included)
Mounting Orientation
Vertical (typical)
Dimensions
Refer to
Minimum Clearance
Airflow
~25 mm
Connectors
~100 mm
Operating Temperature
Refer to
Section 1.3. Environmental Specifications
Drive IP Rating
IP20
iXC6e/XC6e Hardware Manual
1.2. Mechanical Specifications
www.aerotech.com
21
Содержание Automation1 iXC6e
Страница 1: ...Revision 1 04 Automation1 iXC6e and XC6e High Powered PWM Digital Drives HARDWARE MANUAL...
Страница 63: ...Figure 2 28 PSO Interface iXC6e XC6e Hardware Manual 2 5 2 Position Synchronized Output PSO www aerotech com 63...
Страница 86: ...Figure 3 2 Digital Outputs Schematic EB1 3 1 Digital Outputs EB1 iXC6e XC6e Hardware Manual 86 www aerotech com...
Страница 104: ...This page intentionally left blank Appendix B Revision History iXC6e XC6e Hardware Manual 104 www aerotech com...
Страница 112: ...Index iXC6e XC6e Hardware Manual This page intentionally left blank 112 www aerotech com...