11. 

Install cover lock. The combination lock is factory preset to open at 0-0-0. If you want to 

change the combination, push and hold the button down, then advance each number to the 
desired combination. Once a new combination is chosen, insert the lock wire and release button. 
 

DANGER: Risk of Accidental Drowning. Always leave the cover locked and in place when 
the spa is not in use. Extreme caution must be exercised to prevent unauthorized access 
by children. To avoid accidents, ensure that children cannot use this spa unless they are 
supervised at all times. 

 

OPERATION:

 

Before operating the spa, you must ensure the water level in the spa is at the water level fill line 
printed on the spa wall. Never dry-run the power pack as such type of operation will void the 
warranty.  
 

 
CONTROL PANEL FUNCTIONS: 
 
1.

“BUBBLE” button: Activates air jet system.

 

 
2.

“FILTER” button: Activates filter system. 

 
3.

“HEATER” button: Activates heating and filtering system 

at the same time. 

 
4.

“TEMP” button: Sets and displays set temperature. 

 
5.

“ 

 ” button: Higher temperature. 

 
6.

“ 

 ” button: Lower temperature. 

 

7. 

LED Display: Once powered-up, the LED displays the 

current water temperature automatically. 

 
 

 

 

 

                     

                                         

10

 

 

     

CONTROL PANEL 

Содержание PH050006

Страница 1: ...Owner s Manual Model PH050006 Manufactured By Shanghai Qinxu Plastics Products Co Ltd No 5151 Dongchuan Road Heqing Town Pudong New Area Shanghai CN 201201...

Страница 2: ...pply provide a properly located receptacle WARNING No part of the appliance is to be located above the spa pool during use WARNING The electrical plug of the spa should be connected at least 11 5 feet...

Страница 3: ...r a healthy adult Lower water temperatures are recommended for young children and when spa use exceeds 10 minutes B Since excessive water temperatures have a high potential for causing fetal damage du...

Страница 4: ...spray CAUTION Place only on surface that can withstand the floor loading requirements of your spa SAVE THESE INSTRUCTIONS SPECIFICATIONS Model PH050006 Seating capacity Up to 4 Adults Water capacity 8...

Страница 5: ...apable of uniformly supporting this weight for the entire time the spa is installed If the spa is placed on a surface which does not meet these requirements any damage caused by improper support will...

Страница 6: ...could damage it and that the location is level so the spa sits stably and properly 2 During filling emptying or when in use water may spill out of the spa Therefore the spa should be installed near a...

Страница 7: ...Make sure both are right side up 2 Open the air outlet on the spa located next to the Control Panel Screw one end of the inflation hose onto it 3 Open the air valve on the spa wall Connect the other...

Страница 8: ...s in steps 2 5 above accordingly 6 Remove the inflation hose from the air valve on the spa wall and replace the valve cap tightly 7 Remove the inflation hose from the air outlet and replace the outlet...

Страница 9: ...re that children cannot use this spa unless they are supervised at all times OPERATION Before operating the spa you must ensure the water level in the spa is at the water level fill line printed on th...

Страница 10: ...20 C 68 F to 40 C 104 F 3 After turning off the heating system the filtration system will turn off This is normal But if you press the FILTER on before pressing HEATER on by pressing the HEATER button...

Страница 11: ...CI power cord from the electrical receptacle before attempting to clean filter 2 Unscrew the filter cartridge by turning counterclockwise 3 Remove the filter cartridge cover 2 3 4 The filter cartridge...

Страница 12: ...ly run in this mode until water stops exiting the inflation hose Never dry run the power pack as such type of operation will void the warranty 4 Once the above steps are completed unscrew the inflatio...

Страница 13: ...s to help you to diagnose and rectify some common sources of trouble Problem Probable causes Solutions Power pack does not operate Power failure GFCI tripped Check power source Reset GFCI Check if the...

Страница 14: ...ose which can not be negated or limited by law of the state in which the product is used The manufacturer does not authorize or permit any party including its agents distributors or dealers to assume...

Отзывы: