Air Coil Nailer MCN70     

      www.aeroprotools.com 

 

 

 

 

 

 

 

 

 

 

 

AIR-POWERED COIL NAILER 

                                      Model No.:    MCN70 
 
 
 

 

 

                                                                         

  Residual risks 

Even  when  the  tool  is  used  as  prescribed  it  is  not  possible  to  eliminate  all  residual  risk  factors.  The 
following hazards 

may arise in connection with the tool’s construction and design: 

  Damage to lungs if an effective dust mask is not worn.   

 

 

  Damage to hearing if effective hearing protection is not worn. 

 

 

  Health defects resulting from vibration emission if the power tool is being used over longer period of time or not 

adequately managed and properly maintained. 

 

 

Wear eye protection. 

 

 

 

2014 

OPERATING  INSTRUCTIONS  FOR  FASTENER  DRIVING 

TOOLS OPERATED BY COMPRESSED AIR

 

IMPORTANT:   

Read  all  safety  rules  and  operating 
Instructions carefully before first use it.   
Keep this Manual for future reference. 

Содержание MCN70

Страница 1: ...o lungs if an effective dust mask is not worn Damage to hearing if effective hearing protection is not worn Health defects resulting from vibration emission if the power tool is being used over longer period of time or not adequately managed and properly maintained Wear eye protection 2014 OPERATING INSTRUCTIONS FOR FASTENER DRIVING TOOLS OPERATED BY COMPRESSED AIR IMPORTANT Read all safety rules ...

Страница 2: ...personal safety and preventing equipment problems it is very important to read this manual carefully and understand it thoroughly before using the product the symbols listed below are used to indicate this information DANGER Potential hazard that will result in serious injury or loss of life WARRNING Potential hazard that could result in serious injury or loss of life CAUTION Potential hazard that...

Страница 3: ... switch or safety valve for any reason They have been preset at the factory for this compressor s maximum pressure Tampering with the pressure switch or the safety valve may cause personal injury or property damage Risk of burns The pump and the manifold generate high temperatures In order to avoid burns or other injuries do not touch the pump the manifold or the transfer tube while the compressor...

Страница 4: ... parts Do not use the tool near or below freezing temperatures as doing so may cause tool failure Do not store the tool in a freezing environment to prevent ice formation on the operating valves of the tool as doing so may cause tool failure Handling and storage of oil Use with adequate ventilation Avoid contact of oil with eyes skin and clothing Avoid breathing spray or mist Store in a tightly cl...

Страница 5: ... 6 to 8 bar 87 to 120psi Do not exceed the maximum or minimum pressures Operating the tool at the wrong pressure too low or too high will cause excessive noise or rapid wear of tool WARNING Potential hazard that could result in serious injury or loss of life Keep hands and other parts of the body away from the tools discharge and working areas when connecting the air supply Failure to comply could...

Страница 6: ...ygen carbon dioxide or any other combustible or bottled gas to power this tool Do not use this tool in the presence of any flammable liquids or gases Keep hands and other parts of the body away from the firing head during use Do not point the tool towards the operator or other people Never attempt to clear a jammed fastener while the air hose is connected Do not drive a fastener on top of an exist...

Страница 7: ... the muzzle is not pointing towards the operator or any other person or animals 4 4 Handling the tool Pay attention to 2 Special Reference of these operating instructions Having checked that the fastener driving tool is functioning correctly apply the tool to a work piece and actuate the trigger Check whether the fastener has been driven into the work piece in accordance with the requirements if t...

Страница 8: ...gular lubrication if your tool without using the in liner automatic oilier place 2 or 6 drops of pneumatic tool oil into the air inlet before each work day or after 2 hours of continuous use depending in the characteristic of workpiece or type of fasteners Air operated tools must be inspected periodically and worn or broken parts must be replaced to keep the tool operating safely and efficiently C...

Страница 9: ... 1 Tighten screws 2 Check and replace O rings or bumper Air leak between body and cylinder cap 1 Loose screws 2 Worn or damaged O rings or seals 1 Tighten screw 2 Check and replace O rings or bumper Blade driving fastener too deep 1 Worn bumper 2 Air pressure is too high 1 Replace bumper 2 Adjust the air pressure Tool does not operate well can not drive fastener or operate sluggishly 1 Inadequate ...

Страница 10: ...10 Air Coil Nailer MCN70 www aeroprotools com Explode drawing Parts list ...

Страница 11: ...shaft pin 1 14 03 04 27 130 cylinder 1 66 03 04 05 190 spring pin 3x12 1 15 03 04 01 188 o ring 56x3 1 1 67 03 04 36 273 compressed spring 1 16 03 04 19 163 stain ring 1 68 03 04 17 122 limited blocker 1 17 03 04 01 211 o ring 88x3 1 69 03 04 24 029 torsion spring 1 18 03 04 01 275 o ring 56x5 7 1 70 03 04 33 015 nail pusher 1 19 03 04 26 210 gun body 1 71 03 04 31 119 shaft pin 1 20 item no 72 03...

Страница 12: ...magazine 1 40 O ring 6x1 9 1 92 03 04 40 358 nail head protecter 1 41 O ring 6 4 2 1 93 03 04 29 188 gasket shaft 1 42 Valve bush 101 03 04 06 130 gasket 1 43 O ring 8 9x1 9 102 03 04 05 198 spring pin 3x22 1 44 compressed spring 103 quick coupler 1 45 O ring 2 5 1 5 104 03 04 05 071 bolt M5X5 1 46 switch shaft 1 47 Switch sleeve 1 48 03 04 19 107 outer bumper 2 49 03 04 19 106 inner bumper 1 50 0...