background image

AEROMOTIVE  

Part # 15632 & 15633 

 INSTALLATION INSTRUCTIONS 

 

AEROMOTIVE, INC. 

7805 Barton Street, Lenexa, KS 66214 

913-647-7300  fax 913-647-7207 

www.aeromotiveinc.com 

 

CAUTION: 

Installation of this product requires detailed knowledge of automotive systems and repair procedures. We recommend that 
this installation be carried out by a qualified automotive technician. 
Installation  of  this  product  requires  handling  of  gasoline.  Ensure  you  are  working  in  a  well-ventilated  area  with  an 
approved fire extinguisher nearby. Extinguish all open flames, prohibit smoking and eliminate all sources of ignition in the 
area of the vehicle before proceeding with the installation. 
When  installing  this  product,  wear  eye  goggles  and  other  safety  apparel  as  needed  to  protect  yourself  from  debris  and 
sprayed gasoline. 
Some late model vehicles use electronic sensors in their pressure and temperature senders for engine control functions. 
Before 
removing  the  original  senders,  we  recommend  that  you  contact  your  Auto  Dealer  to  be  sure  no  critical  functions  will  be 
disrupted. With pressure gauges, it is beneficial to add a T-fitting to install your new gauge and to keep the warning light 
operational. This allows you to monitor the pressure and still have a warning light to indicate emergency conditions 

 

WARNING! 

The  fuel  system  is  under  pressure.  Do  not  open  the  fuel  system  until  the  pressure  has  been  relieved.  Refer  to  the 
appropriate vehicle service manual for the procedure and precautions for relieving the fuel system pressure. 

 
Aeromotive system components are not legal for sale or use on emission-controlled motor vehicles. 

 

Installation: 

1. 

Locate pressure port. This gauge is designed for 1/8" NPT. In some cases, an 
adapter may be necessary 

2. 

Install T-fitting if needed to share test port with additional gauge(s) 

3. 

Ensure the regulator is mounted with the gauge face vertical, at the right angles 
to the ground, with the Vent Valve at the top. 

4. 

Apply Teflon sealing compound to insure a leak-free connection. 

5. 

Install gauge into pressure port, being careful not to over tighten. 

6. 

After installation, start engine and check all connections for leaks. 

 

Operation: 

Your gauge may be equipped with an external vent valve for the purpose of venting the gauge. Changes in temperature and 
environmental pressure can affect how a liquid filled gauge reports pressure. Your new Auto Meter liquid filled gauge may be 
equipped with a unique vent valve 
that allows gauge pressure to be equalized to atmosphere, as needed, insuring accurate pressure readings regardless of operating 
conditions. 
 
To vent the gauge case, push the black band back covering the vent valve head and gently lift it up slightly, DO NOT REMOVE THE 
VALVE.
 
Once the valve is raised, gauge case pressure is again equalized to atmosphere, and reported pressure will be accurate. Please 
push the stem back down and replace the black retaining band immediately after equalizing pressure to reseal the gauge and help 
retain the valve during vehicle operation. 
 
NOTE: The gauge must be mounted with the gauge face vertically, (or as close to 90° to the ground as possib le) with the 
vent on 
top. This is to prevent the gauge from leaking during venting. 

 

 

NOTE: This liquid filled gauge is not intended to be 100% full of liquid. When held vertical, the level can appear to be 

between 3/4 and 7/8 full.

 

 

 

Содержание 15632

Страница 1: ...ale or use on emission controlled motor vehicles Installation 1 Locate pressure port This gauge is designed for 1 8 NPT In some cases an adapter may be necessary 2 Install T fitting if needed to share...

Страница 2: ...ale or use on emission controlled motor vehicles Installation 1 Locate pressure port This gauge is designed for 1 8 NPT In some cases an adapter may be necessary 2 Install T fitting if needed to share...

Страница 3: ...ale or use on emission controlled motor vehicles Installation 1 Locate pressure port This gauge is designed for 1 8 NPT In some cases an adapter may be necessary 2 Install T fitting if needed to share...

Страница 4: ...ale or use on emission controlled motor vehicles Installation 1 Locate pressure port This gauge is designed for 1 8 NPT In some cases an adapter may be necessary 2 Install T fitting if needed to share...

Страница 5: ...tive will then at it s sole discretion return repair or replace the product If any Aeromotive product is determined defective buyer s exclusive remedy is limited in value to the sale price of the good...

Страница 6: ...tive will then at it s sole discretion return repair or replace the product If any Aeromotive product is determined defective buyer s exclusive remedy is limited in value to the sale price of the good...

Страница 7: ...tive will then at it s sole discretion return repair or replace the product If any Aeromotive product is determined defective buyer s exclusive remedy is limited in value to the sale price of the good...

Страница 8: ...tive will then at it s sole discretion return repair or replace the product If any Aeromotive product is determined defective buyer s exclusive remedy is limited in value to the sale price of the good...

Отзывы: