background image

Aerohive QuickStart for the AP370 and AP390

This guide explains how to install an Aerohive AP370 or AP390 access point so it can make a network 
connection to HiveManager. The instructions in this document apply to both models. To register, get 
the latest product documentation, (including translations of select documents), see compliance 
information, and download software updates, visit www.aerohive.com/support.

©

2013 Aerohive Networks, Inc.

Aerohive

®

 is a U.S. registered trademark of Aerohive Networks, Inc.

P/N 330102-01 Rev. A

You can mount the AP370 or AP390 on a dust-free surface, on a wall, or to the tracks of a 
dropped ceiling grid that will support its weight (AP370: 1 lb or .45 kg; AP390: 20 oz or .57 kg). The 
wall and ceiling mounting options are explained below and on the next panel.

 

Mounting the AP370 and AP390

Cut a small hole in the ceiling tile to accommodate the cables. Connect the cables and, 
for optimal reception, align external antennas for the AP390 as shown below. 

The status LED on the top of the device displays the following activity states:

• Dark: Power is off, or the indicator has been disabled.

• Amber (fl ashing): The device is performing a fi rmware upgrade. Do not power off the device 

during this process.

• Amber (solid): This indicates that the CAPWAP connection has not been successfully 

established, or the device is booting or shutting down.

• White: The device is powered on and operating properly, and has made a successful 

CAPWAP connection through the ETH0 interface.

Status LED

You can mount the AP370 or AP390 to the tracks of a dropped ceiling grid using the 
mounting tabs and clips on the back of the device.  The tabs slip over the edge of the 
ceiling track and the clips click into place to secure the device.

The ceiling mounting options are shown below. 

The mounting hardware on the device 

allows you to mount it diagonally, or square to the track.

Ceiling Mount

To mount the device on a ceiling track in either the diagonal or square position, hold the device 
so that you are touching the appropriate tabs (as shown in the previous illustrations). Hold the 
device upside down and press it gently against the ceiling track. Use your fi ngers to guide one 
of the tabs over the edge of the track. Then rotate the device counter-clockwise (facing the 
device) until the clips click into place.  

To remove the device, press the clips toward the device until they disengage from the track, 
then rotate the device gently and pull it away from the track. 

The illustrations below show how to install the device on a ceiling track in the diagonal position. 
To mount the device the square position, use the square-mount tabs and clips and follow the 
same steps. 

Use your fi ngertips to align the tabs 
with the track. 

1

2

Rotate the device until the 
clips click into place.

You can secure the AP using a Kensington lock, or you can use the security bracket and screw 
that ships with the device to secure it to a ceiling track or to a wall, as shown in the illustrations 
below. To use a Kensington lock, loop the lock cable around a secure object, insert the T-bar 
component of the lock into the lock slot on the AP and then turn the key to engage the lock. 

To secure the AP to a ceiling track or a wall using the security bracket and screw, you will need 
a spanner bit for size #6 security screws, and a driver handle that will accept the bit. Bits are 
available from Aerohive in sets of three (AH-ACC-SEC-BIT-300-100-3PK). To use the security screw, 
refer to the illustrations below. If you use a slotted screw, you will need a fl at-blade screwdriver.

Aerohive recommends the following Kensington lock models:

•  NOTE: This list to be completed after PVT phase.

 

Locking the Device

Diagonal mount 
lock slot

Square mount 
lock slot

5GHz(0)

Kensington
lock slot

Guide security bracket along the 
lock slot until the screw holes align 
and the end of the bracket slips 
under the clip.  

Clip

Security 
bracket 

Security 
screw 

Aligning AP390 External Antennas

Diagonal 
mount clip

Diagonal 
mount clip

Diagonal mount tab 
(under fingertip)

CLICK!

CLICK!

Diagonal mount 
tab (under 
fingertip)

Note: For a square mount, 
rotate in the opposite 
direction.

Ceiling track

Diagonal installation

Square installation

You can attach the AP to any surface that supports its weight 
(less than x lb or .xx kg for either device), and to which you can 
install M4 mounting screws. There are four wall mount slots on 
the back of the device. Measure the distances between the 
centers of these slots and drill corresponding holes in the wall, or 
use the template in the Aerohive Hardware Reference Guide at 
www.aerohive.com/support/tech-docs-and-online-training to 
mark the drill holes. Install size M4 screws. If you are connecting 
to cables from inside the wall, drill a hole in the wall so that you 
can pass the cables through to the AP. Finally, connect the 
cables to the device.

Wall Mount

Wall mount slots

Diagonal 
mount clip 
and tab

Square 

mount clip 

and tab

Diagonal 

mount clip 

and tab

Tab

Clip

Square 
mount clip 
and tab

After you power on the AP, it automatically tries to get network settings and contact HiveManager. 
This process takes about fi ve minutes. When you see the AP listed on the All Devices page in the 
Monitor section of the HiveManager GUI, the initial setup is complete and you can begin managing 
the AP using HiveManager. 

If the AP does not appear after about ten minutes, see the Aerohive product documentation and 
computer-based training modules to learn what you can do to help establish the connection. These 
resources are available for free at www.aerohive.com/support/tech-docs-and-online-training.

Switch

DHCP 

server

Firewall

Internet

Some other network devices (They 
might all be incorporated in the same 
device, such as a router or firewall.)

1

Ethernet 

cable

2

ETH0

Connect a standard 
RJ45 Ethernet cable 
from ETH0 on the AP to 
a switch.

3

For AP390 models, attach external antennas 
to the 5 GHz and 2.4 GHz connectors.

AP370

Connecting the Device

If the switch provides 
PoE, cabling the AP to the 
switch will cause the AP to 
power on in a few seconds.

If the switch does not provide PoE, 
use the AC/DC power adaptor, power 
supply, or PoE injector (all available 
as accessories).

AP370 Kit Contents
•  AP370 device with USB
    slot cover installed
•  2 security screws
•  2 slotted screws
•  1 security bracket
•  QuickStart Guide

AP390 Kit Contents
•  AP390 device with USB slot
    cover installed
•  2 security screws
•  2 slotted screws
•  1 security bracket
•  QuickStart Guide
(Antennas must be ordered 
separately)

Optional Accessories

You can order the following accessories for AP370 and AP390 devices:

NOTE: This list to be completed after PVT phase.

•  PoE injector and AC power adapter - (12Vdc, 2A or 55Vdc, 0.6A/PoE)

•  Optional mounting brackets for non-standard ceiling tracks: 

  

15/16" 

recessed

   

3/8" fl ushed and recessed

   

9/16" fl ushed and recessed, 

•  Plenum and suspend mount kits

45°

90° to wall 

straight

straight

straight

45°

straight

90° to 
ceiling

Ceiling 
mount

Wall 
mount

45°

45°

WARNING: FOR INDOOR USE ONLY. The AP370 and AP390 devices, DC power 
adapter and all connected cables are designed for indoor use only.

Содержание AP370

Страница 1: ...se the security screw refer to the illustrations below If you use a slotted screw you will need a flat blade screwdriver Aerohive recommends the following Kensington lock models NOTE This list to be c...

Страница 2: ...equipment should be installed and operated with a minimum distance of 2 FP between the radiator and your body if using AP170 directional antenna part number AH ACC 170 ANT 18 the distance is 65cm Thi...

Страница 3: ...dans cette liste ou dont le gain est sup rieur au gain maximal indiqu sont strictement interdits pour l exploitation de l metteur Avertissement Le dispositif fonctionnant dans la bande 5150 5250 MHz...

Страница 4: ...cense requirements for each European Community country as described in this section HiveAPs can be operated indoors or outdoors in all countries of the European Community using the 2 4 GHz band Channe...

Страница 5: ...s disposi es da Directiva 1999 5 CE Slovenian Aerohive izjavlja da je ta Radio LAN device v skladu z bistvenimi zahtevami in ostalimi relevantnimi dolo ili direktive 1999 5 ES Spanish Por medio de la...

Страница 6: ...s HiveAP die folgenden Sicherheitsanweisungen durchlesen Warnung Die Installation und der Ausbau des Ger ts darf nur durch Fachpersonal erfolgen Das Ger t sollte nicht an eine ungeerdete Wechselstroms...

Страница 7: ...TS China SRRC CMIIT 2011AJ7102 Hong Kong OFTA Certificate No HK0011200428 Chile Certificate ORD No 2129 DFRS04348 F 50 Saudi Arabia Product Conformity Programme PCP Registration Number KSA R 103282 C...

Отзывы: