Insert the roof hook
with the T-Bolt Assembly into the channel of the base plate bridge
.
The horizontal distance between the rafter and the roof hook must not exceed 140 mm.
Position the roof hook horizontally in the valley of the roof tile.
Position the roof hook vertically:
Distance A: min. 2 mm
Distance B: min. 5 mm
Tighten the Allen screw
to 15 Nm or 11 ft-lb.
Close roofing
Make sure that the roof hooks are aligned horizontally and vertically.