aero pure VSF110D-S Скачать руководство пользователя страница 1

 

BATHROOM FAN   

www.aeropurefans.com   

MODEL: VSF110D-S   

WARNING   

WARNING- TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, PLEASE READ 
THE FOLLOWING PRIOR TO INSTALLING THE FAN:   

1

.  Use  this  unit  only  in the manner intended  by  the  manufacturer.  If  you  have  questions,  contact  the manufacturer.   

2

.  Before 

servicing  or  cleaning  unit,  switch  power  off  at  service  panel  to  prevent  power  from  being  switched  on  accidentally.  When  the 
service disconnect cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.     

3

.  Installation  work  and  electrical  wiring  must  be  done  by  a  licensed  person(s)  in  accordance  with  all  applicable  codes  and 

standards,  including  fire-rated  construction  codes  and  standards.   

4

.  Sufficient  air  is  needed  for  proper  combustion  and 

exhausting  of  gases  through  the  flue  (chimney)  of  fuel  burning  equipment  to  prevent  backdraft.  Follow  the  heating  equipment 
manufacturer’s guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and 
the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.     

5

. When  cutting  or  drilling  into  wall  or  ceiling,  do  not  damage  electrical  wiring  and  other  hidden  utilities.   

6

.  Ducted  fans  must 

always be vented to the outdoors.   

7

.Unit is acceptable for use over a tub or shower when connected to a GFCI (Ground Fault 

Circuit Interrupter) protected branch circuit (ceiling installation only).   

8

. This unit must be grounded.   

9

. Not for use in kitchens.   

10

. Install fan at least 2.5 m (8.2 feet) above the floor.   

11

. To reduce risk of fire and to properly exhaust air, be sure to duct air 

outside.  Do  not  vent  exhaust  air  into  spaces  within  walls  or  ceilings  or  into  attics,  crawl  spaces,  or  garages.  This  unit  is 
appropriate for wall installation in a non-wet application. 

12

. WARNING: To reduce the risk of fire or electric shock, do not use 

this fan with any solid-state speed control device.   

13

. The fan must not be installed in a ceiling thermally insulated to a value 

greater than R40. 

CAUTION   

1

.  For  general  ventilating  use  only.  Do  not  use  to  exhaust  hazardous  or  explosive  materials  and  vapors.   

2

.  This  product  is 

designed for installation in ceilings up to a 12/12 pitch (45 degree angle).    Duct connector must point upward for wall application. 

3

. To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall spray, construction dust, etc. off power 

unit.   

4

. Please read specification label on product for further information and requirements.   

*

The manual in electronic format may be downloaded from our company website or obtained from the dealer.   

CLEANING & MAINTENANCE   

For quiet and efficient operation, long life, and attractive appearance  - lower or remove grille and vacuum interior of unit with the 
dusting brush attachment.   

The motor is permanently lubricated and never needs oiling.   

OPERATION   

User setting   

The  control  box,  located  inside  the  fan  housing,  has  one  separate 
adjustment:  the  toggle  switch,  which  will  adjust  the  upper  fan  speed 
setting from 80 to 140 CFM. 

Timer  delay 
Low airflow   

 
knob   

+ +   
 

S   

12   
3   
 

T   

Power  box 

Toggle switch   

Switch   

position 

1 2 3 

1 2 3 

1 2 3 

1 2 3 

1 2 3 

1 2 3 

1 2 3 

1 2 3 

Air deliver (CFM) 

80  90  110 120  90  110 120  140 

1 2 3 

 

Duct   

 
diameter   

 

4"   

 
4"   

 
4"   

 
4"   

 
6"   

 
6
"   

 
6"   

 
6"   

(inches)   

How to Work   

To Turn Fan ON 

Turn the Wall Switch (according to the follow

ing “CONNECT ELECTRICAL 

WIRING”) ON. 

.   

Factory setting: 110CFM ( 

with 6" duct 

To Turn Fan OFF 

Turn the Wall Switch OFF 

916, and 920.   

Other airflow reference performance based on HVI 
Procedures 915, 916, and 920.   

READ AND SAVE THESE INSTRUCTIONS   

Installer: Leave this manual with the homeowner.   

1   

 

Airflow       
(CFM)       

80      90    110    120      90    110    120    140 

  Duct 
Diameter 
(inches) 

4”      4”      4”      4”      6”      6”      6”      6” 

1 2 3      1 2 3      1 2 3      1 2 3    1 2 3      1 2 3    1 2 3      1 2 3 

 

Содержание VSF110D-S

Страница 1: ... unit is appropriate for wall installation in a non wet application 12 WARNING To reduce the risk of fire or electric shock do not use this fan with any solid state speed control device 13 The fan must not be installed in a ceiling thermally insulated to a value greater than R40 CAUTION 1 For general ventilating use only Do not use to exhaust hazardous or explosive materials and vapors 2 This prod...

Страница 2: ... through the hole A and hole B Screw the hanger bar onto the other side of joist through the hole refer to diagram at right Screw hanger bar to housing with screw A Screw A Hanger Bar Options Screw B Distance A Hanger Bar Channel Screw A Screw A 13 1 4 in to 15 1 2 in 336mm 394mm Hanger bar short Channel A Fig 1 16 1 2 in to 18 7 8 in 419mm 480mm Hanger bar long Channel B Fig 2 Fig 1 Fig 2 3 Mount...

Страница 3: ...N BRN SWITCH I FAN WIRE SWITCH I UNIT BLK PANEL SWITCH II FAN RECEPTACLE SWITCH II SWITCH BOX POWER SUPPLY 1 20V AC INSTALL GRILLE Install ceiling material to complete ceiling construction Then cut around the fan housing To attach the grille assembly to the fan housing pinch the grille springs on the sides of the grille assembly and position the grille into the housing with the grille springs in t...

Страница 4: ... proof of date of purchase This warranty is covered to the original retail purchaser of this product only The manufacturer will replace any mechanical or electrical part that proves defective in normal household use for a period of 72 months THIS WARRANTY DOES NOT COVER Damages from improper installation Damages from shipping Damages from misuse abuse accident alteration lack of proper care and ma...

Отзывы: