WARNING

 

APPROVED FOR BOTH CEILING AND WALL INSTALLATION

 

 

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, PLEASE READ THE FOLLOWING:

 

 

1

. Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer at the address

 

or 

telephone  number  listed  in the warranty. 

2

.  Before  servicing  or cleaning  unit,  switch  power  off at  service  panel  and  lock  the service 

disconnecting  means  to  prevent  power  from  being  switching  on  accidentally.  If  the  service  disconnecting  means  cannot  be  locked, 
securely fasten a prominent warning device, such as a tag, to the service panel. 

3

. Installation work and electrical wiring must be done 

by a licensed person(s) in accordance with all applicable codes and standards, including fire-rated construction codes and standards. 

4

.  Sufficient  air  is  needed  for  proper  combustion  and  exhausting  of  gases  through  the  flue  (chimney)  of  fuel  burning  equipment   to 

prevent  backdra

ft.  Follow  the  heating  equipment  manufacturer’s  guideline  and  safety  standards  such  as  those  published  by  the 

National  Fire  Protection  Association  (NFPA),  and  the  American  Society  for  Heating,  Refrigeration  and  Air  Conditioning  Engineers 
(ASHRAE),  and  the  local  code  authorities. 

5

. When  cutting  or  drilling  into  wall  or  ceiling,  do  not  damage  electrical  wiring  and  other 

hidden utilities. 

6.

 Ducted fans must always be vented to the outdoors.

 

 

7

.  Acceptable  for  use  over  a  tub  or  shower  when  connected  to  a  GFCI  (Ground  Fault  Circuit  Interrupter)  protected  branch 

circuit.

 8

. This unit must be grounded.

 9

. Never place a switch where it can be reached from a tub or shower.

 10

. Not for use in 

kitchens.

 11

. Install fan at least 2.5 m (8.2 feet) above the floor.

 12

. WARNING: To reduce the risk of fire or electric shock, do 

not use this

 

fan with any solid-state speed control device. 

13

. The fan must not be installed in a ceiling thermally insulated to a 

value greater than R40.

 

 

CAUTION

 

 

1

. For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.

 

 

2

. This product is designed for installation in ceilings up to a 12/12 pitch (45 degree angle). Duct connector must point up for 

wall

 

application.

 

 

3.

 

To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall and construction dust away of motor 

unit.

  

4. Please read specification label on product for further information and requirements. 

 

CLEANING & MAINTENANCE

 

 

For quiet and efficient operation, long life, and attractive appearance, lower or remove grille and vacuum interior of unit with 
the dusting brush attachment.

 

 

The motor is permanently lubricated and never needs oiling.

 

 

OPERATION

 

 

The fan and light can be operated separately. Use a 2-function wall control. S

ee “Connect Wiring” for details.

 

 

ASSEMBLY INSTRUCTIONS

 

 

MOUNT DIRECTLY TO JOIST OR I-JOIST

 

 

Place the housing assembly in the opening so the bottom edge is flush with the finished ceiling. Nail the housing assembly to 
the joist using nails.

 

POSITION THE HOUSING ASSEMBLY

 

 

Position the housing assembly against the joist. With a pencil,  
trace an outline of the housing assembly onto the ceiling. Set  
the housing aside, and cut out an opening for the fan.

 

 

Note:hold the housing position 5/16" above the ceiling edge.

 

 

 

 

 
 

Housing

 

 

Ceiling

 

 

5/16in.

 

CONNECT ELECTRICAL WIRING

 

 

Run 120 V AC house wiring to the location of the fan. Use only UL-approved connectors (not included) to attach the house wiring to the wiring plate. 
Refer to the wiring diagram, and connect the wires as shown.

 

 

BLACK(BLK)

 

WHITE(WHT)

 

 

BLUE(BLU)

 

GROUND (GRD)

 

 

LIGHT

 

PANEL

WIRE

 

UNIT

 

 

 

 

FAN

 

 

FAN

 

RECEPTACLE

 

 

 

 

 

SWITCH BOX

 

 

LIGHT

 

 

RECEPTACLE

 

 

 

 

POWER SUPPLY

 

 

 

 

120V AC

 

 

 

 

 