VENTILATION FAN

 

 
         
           

MODEL: AP90-SL & AP90H-SL       

                         

AP120-SL & AP120H-SL 

 
 

   

WARNING 

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, PLEASE READ THE FOLLOWING: 
1.Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer at the address or 
telephone number listed in the warranty. 2. Before servicing or cleaning unit, switch power off at service panel and lock the service 
disconnecting means to prevent power from being switching on accidentally. If the service disconnecting means cannot be locked, 
securely fasten a prominent warning device, such as a tag, to the service panel. 3. Installation work and electrical wiring must be 
done by a licensed person(s) in accordance with all applicable codes and standards, including fire-rated construction codes and 
standards. 4. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning 
equipment to prevent backdraft. Follow the heating equipment manufacturer’s guideline and safety standards such as those 
published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air 
Conditioning Engineers (ASHRAE), and the local code authorities. 5. When cutting or drilling into wall or ceiling, do not damage 
electrical wiring and other hidden utilities. 6. Ducted fans must always be vented to the outdoors. 7. Acceptable for use over a tub or 
shower when connected to a GFCI (Ground Fault Circuit Interrupter) protected branch circuit (ceiling installation only). 8. This unit 
must be grounded. 9. Never place a switch where it can be reached from a tub or shower. 10. Not for use in kitchens. This unit may 
be installed in a wall for a non- wet application. 11. Install fan at least 2.5 m (8 feet) above the floor. 12 WARNING: To reduce the risk 
of fire or electric shock, do not use this fan with any solid-state speed control device. 13. The fan must not be installed in a ceiling 
thermally insulated to a value greater than R40. 

CAUTION 

1. For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors. 
2. This product is designed for installation in ceilings up to a 12/12 pitch (45 degree angle). Duct connector must point up for wall 
application. 
3. To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall and construction dust off power unit. 
4. Please read specification label on product for further information and requirements. 
 

CLEANING & MAINTENANCE 

For quiet and efficient operation, long life, and attractive appearance, lower or remove grille and vacuum interior of unit with the 
dusting brush attachment. 
The motor is permanently lubricated and never needs oiling. 
 

OPERATION 

See “Connect Wiring” for details. (AP90/120-SL) 
The humidity control and fan and light can be operated separately. Do not use a dimmer switch to operate the humidity control or 
light. 

See “Connect Wiring” for details. (AP90/120H-SL) 

Humidity Sensor For

 

AP90/120H-SL

       

SENSOR OPERATION 

The humidity-sensing fan uses a sophisticated humidity sensor that responds to: (a) rapid to moderate (user-adjustable) 
increases in humidity or (b) humidity above a user-adjustable set-point (50%-100% relative humidity). The humidity sensor 
may occasionally turn the fan ON when environmental conditions change. If the fan continuously responds to changing 
environmental conditions, “H” (means “humidity”) adjustment may be required. This figure is factory-set for about 75% RH. 

SENSITIVITY ADJUSTMENT 

The “H” has been factory set for most shower applications. However, if the fan is in a tub area or is being used for dampness 
control, the “H” may need to be increased toward maximum “+”. If the control is responding too often to changing 
environmental conditions, movement toward less “-” “H” may be required. 
To adjust the “H”: 
1. Disconnect power at service entrance. 
2. Through the grille, locate the slot marked “H”. 
3. Carefully rotate the “H” adjustment toward “+” or “-”. 
4. Turn on power and check operation by turning on the shower or other humidity source until the fan turns on. 
5. Repeat above steps if necessary. 
When the temperature changes, humidity sensor values will have deviation. 

TIMER ADJUSTMENT 

The humidity sensing fan has a “T” (means timer) that can be adjusted from 5 to 60 minutes (factory-set at about 20 minutes). 
This “T” controls the length of time that the fan remains ON after the sensor has stopped sensing a rise in humidity 
and the humidity level is below the user-adjustable set-

point. To adjust the “T”: 

1. Disconnect power at service entrance; 
2. Through the grille, locate the slot marked “T”; 
3. Carefully rotate the “T” adjustment to desired setting (from 5 to 60 minutes). 
4. Check operation by turning on a humidity source until the fan turns on. 
5. Turn humidity source off and time the unit. 
6. Repeat above steps if necessary.           

                                                                 

READ AND SAVE THESE INSTRUCTIONS 

                                          Installer: Leave this manual with the homeowner                 

 

Содержание AP90-SL

Страница 1: ...ep drywall and construction dust off power unit 4 Please read specification label on product for further information and requirements CLEANING MAINTENANCE For quiet and efficient operation long life and attractive appearance lower or remove grille and vacuum interior of unit with the dusting brush attachment The motor is permanently lubricated and never needs oiling OPERATION See Connect Wiring fo...

Страница 2: ...g 2 3 Mount with hanger bars only Slide hanger bars onto housing and adjust to fit between framing Extend the hanger bars to the width of the framing Holding the fan in place position the hanger bar tabs close to the bottom edge of the framing Secure hanger bars to framing using one screw on each end of hanger bar refer to the right diagram Screw hanger bars to housing with screw A Hanger Bar A Op...

Страница 3: ...commended Insulation around the ducts can reduce energy loss and inhibit mold growth Fans installed with existing ducts may not achieve their rated air flow CONNECT ELECTRICAL WIRING Run 120V AC house wiring to the location of the fan Use only UL approved connectors not included to attach the house wiring to the wiring plate Refer to the wiring diagram and connect the wires as shown For AP90 120 S...

Страница 4: ...electrician Does not cover any labor or transportation charges related to the repair of this product This warranty does not extend to fluorescent lamp starters and tubes THIS LIMITED WARRANTY IS GIVEN IN LIEU OF ALL OTHER WARRANTIES EXPRESSED OR IMPLIED INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE The remedy provided in this warranty is exclusive and is granted ...

Отзывы: