aero pure AP80RVL Скачать руководство пользователя страница 1

 

MODEL: AP80RVL   

BATHROOM FAN   

www.aeropurefans.com   

WARNING   

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, PLEASE READ THE FOLLOWING:   

CAUTION   

1. For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors. 2. This product is designed for installation 
in ceilings up to a 12/12 pitch (45 degree angle). Duct connector must be horizontal.    **   

DO NOT MOUNT THIS PRODUCT IN A WALL.   

3. To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall spray, construction dust, etc. off power unit. 4. Please read 
specification label on product for further information and requirements.   

CLEANING & MAINTENANCE   

For  quiet  and  efficient  operation,  long  life,  and  attractive  appearance  lower  or  remove  grille  and  vacuum  interior  of  unit  with  the 
dusting brush attachment.   
The motor is permanently lubricated and never needs oiling.   

OPERATION   

Use an on/off switch to operate this fan. See “Connect Wiring” for details

.   

PLAN THE INSTALLATION   

1

. Do not use in a cooking area.   

2. Two ways to connect ductwork to a factory-shipped unit

.   

INSULATION*   

(Place around and 

ROOF CAP* 

over Fan Housing.) 

(with built-in 

damper) 

FAN 

POWER 

HOUSING 

CABLE*   

Keep duct 
runs short   

Seal gaps   
 
around   

Housing.   

ROUND   

DUCT* 

WALL CAP* 

Seal duct 

(with built-in 

*

 Purchase 

joints with 

ROUND 

damper) 

separately 

tape. 

ELBOW(S) * 

READ AND SAVE THESE INSTRUCTIONS 

Installer: Leave this manual with the homeowner

1

.Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer at the address or telephone number 

listed in the warranty. 

2

.Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power 

from being switching on accidentally. If the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, 
to  the  service  panel. 

3

.  Installation  work  and  electrical  wiring  must  be  done  by  a  licensed  person(s)  in  accordance  with  all  applicable  codes  and 

standards, including fire-rated construction codes and standards. 

4

. Sufficient air is needed for proper combustion and exhausting of gases through 

the flue (chimney) of fuel burning equipment to prevent backdraft. Follow the heating equipment manufacturer’s guideline and safety standards such 
as  those  published  by  the  National  Fire  Protection  Association  (NFPA),  and  the  American  Society  for  Heating,  Refrigeration  and  Air  Conditioning 
Engineers (ASHRAE), and the local code authorities. 

5

. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden 

utilities. 

6. 

Ducted fans must always be vented to the outdoors. 

7

. Acceptable for use over a tub or shower when connected to a GFCI (Ground Fault 

Circuit Interrupter) - protected branch circuit. 

8

. This unit must be grounded. 

9

. Never place a switch where it can be reached from a tub or shower.   

10

Not for use in kitchens. 

11

. Install fan at least 2.5 m (8.2 feet) above the floor. 

12. 

WARNING: To reduce the risk of fire or electric shock, 

do not use this fan with any solid-state speed control device. 

13

. The fan must not be installed in a ceiling thermally insulated to a value greater than 

R40. 

Содержание AP80RVL

Страница 1: ...uestions contact the manufacturer at the address or telephone number listed in the warranty 2 Before servicing or cleaning unit switch power off at service panel and lock the service disconnecting means to prevent power from being switching on accidentally If the service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel 3 Installatio...

Страница 2: ...g one screw on each end of hanger bar Attach set screws to lock bar hangers in place Screw B 2 INSTALL ROUND DUCTWORK Connect the round ductwork not included to the damper duct connector and run the ductwork to a roof or wall cap not included Using duct tape not included secure all the ductwork connections so that they are air tight Insulated flexible duct is recommended for the quietest possible ...

Страница 3: ...ing After finishing the ceiling job fill gap between flange and ceiling with caulk or other sealant to prevent air leakage REPLACEMENT INSTALLATION 1 Remove the trim ring by detaching the springs 2 Remove the screws as shown in the right 3 Remove the lamp base 4 Pull the duct system so that you can see the blower system Remove the screws Blower system Lamp base REPLACEMENT INSTALLATION 5 Remove th...

Страница 4: ...R Damages from improper installation Damages from shipping Damages from misuse abuse accident alteration lack of proper care and maintenance Damages from service by persons other than a licensed electrician Does not cover any labor or transportation charges related to the repair of this product This warranty does not extend to fluorescent lamp starters and tubes or any light bulbs THIS LIMITED WAR...

Отзывы: