aero pure AP80-QVL Скачать руководство пользователя страница 1

                                                                                                                                                                   

RECESSED FAN LIGHT

 

MODEL: AP80-QVL                           

 

                                                                                        AP80H-QVL

                                 

 

 

WARNING 

 

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, PLEASE READ THE FOLLOWING: 
1. Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer at the address or 
telephone number listed in the warranty. 2.Before servicing or cleaning unit, switch power off at service panel and lock the service 
disconnecting means to prevent power from being switching on accidentally. If the service disconnecting means cannot be locked, 
securely fasten a prominent warning device, such as a tag, to the service panel. 3. Installation work and electrical wiring must be 
done by a licensed person(s) in accordance with all applicable codes and standards, including fire-rated construction codes and 
standards. 4. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning 
equipment to prevent backdraft. Follow the heating equipment manufacturer’s guideline and safety standards such as those 
published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air 
Conditioning Engineers (ASHRAE), and the local code authorities. 5. When cutting or drilling into wall or ceiling, do not damage 
electrical wiring and other hidden utilities.6.Ducted fans must always be vented to the outdoors. 7. Acceptable for use over a tub or 
shower when connected to a GFCI (Ground Fault Circuit Interrupter) - protected branch circuit. 8. This unit must be grounded. 9. 
Never place a switch where it can be reached from a tub or shower. 10. WARNING: To reduce the risk of fire or electric shock, do not 
use this fan with any solid-state speed control device. 11. The fan must not be installed in a ceiling thermally insulated to a value 
greater than R40. 

CAUTION 

1. For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors. 
2. This product is designed for installation in ceilings up to a 12/12 pitch (45 degree angle). Duct connector must point up for wall 
application. 
3. To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall and construction dust away of motor unit. 
4. Please read specification label on product for further information and requirements. 
 

CLEANING & MAINTENANCE 

For quiet and efficient operation, long life, and attractive appearance, lower or remove grille and vacuum interior of unit with the 
dusting brush attachment. 
The motor is permanently lubricated and never needs oiling. 
 

OPERATION 

Use an on/off switch to operate this fan. See “Connect Wiring” for details. 
The humidity control and fan can be operated separately. Can be used with a dual “stacked” switch for fan / light control. Do not use 
a dimmer switch 

to operate the humidity control or light. See “Connect Wiring” for details. 

For AP80H-RVL 
SENSOR OPERATION 

The humidity-sensing fan uses a sophisticated humidity sensor that responds to: (a) rapid to moderate (user-adjustable) increases in 
humidity or (b) humidity rate above a user-adjustable set-point (50%-100% relative humidity). The humidity sensor may occasionally 
turn the fan ON when environmental conditions change. If the fan continuously responds to changing environmental conditions, 
adjustment may be required. The fan is factory-set for 75% (with a ambient temperature of 77 degree F) 

SENSITIVITY ADJUSTMENT (H) 

The “H” has been factory set for most shower applications. However, if the fan is in a tub area or is being used for dampness control, 
the “H”may need to be increased toward maximum “+”. If the control is responding too often to changing environmental conditions, 
movement toward less “-” “H” may be required. To adjust the “H”: 
1. Disconnect power at service entrance. 
2. Through the grille, locate the slot marked “H”. 
3. Carefully rotate the “H” adjustment toward “+” or “-”. 
4. Turn on power and check operation by turning on the shower or other humidity source until the fan turns on. 
5. Repeat above steps if necessary. 
When the ambient temperature changes, the humidity sensor values will deviate slightly. 

TIMER ADJUSTMENT (T) 

The “T” on the control panel will adjust the time delay from 5 to 60 minutes (factory pre-set at 20 minutes). This “T” controls the 
length of time that the 
fan remains ON after the sensor has stopped sensing a rise in humidity and the humidity level is below the user-adjustable set-point. 
To adjust the “T”: 
1. Disconnect power at service entrance; 
2. Through the grille, locate the slot marked “T”; 
3. Carefully rotate the “T” adjustment to desired setting (from 5 to 60 minutes). 
4. Check operation by turning on a humidity source until the fan turns on. 
5. Turn humidity source off and time the unit. 
6. Repeat above steps if necessary.         

                                                                 

READ AND SAVE THESE INSTRUCTIONS 

                                          Installer: Leave this manual with the homeowner             

AP80-QVL, AP80H-QVL

 

Содержание AP80-QVL

Страница 1: ... CLEANING MAINTENANCE For quiet and efficient operation long life and attractive appearance lower or remove grille and vacuum interior of unit with the dusting brush attachment The motor is permanently lubricated and never needs oiling OPERATION Use an on off switch to operate this fan See Connect Wiring for details The humidity control and fan can be operated separately Can be used with a dual st...

Страница 2: ...the fan with the hanger bar tabs aligned with the bottom edge of the framing holding the ventilator in place Secure hanger bars to framing using one screw on each end of hanger bar Attach set screws to lock bar hangers in place 2 INSTALL ROUND DUCTWORK Connect the round ductwork not included to the damper duct connector and run the ductwork to a roof or wall cap not included Using duct tape not in...

Страница 3: ...rescent bulb or LED bulb Bulb not included 3 The bulb housing can adjust up or down to accommodate different bulbs Unit is qualified with use of GU24 adaptor and use of a GU24 bulb REPLACEMENT INSTA LLATION 1 Remove the trim ring by detaching the springs 2 Remove the screws as shown in the right 3 Remove the lamp base 4 Pull the duct system so that you can see the blower system REPLACEMENT INSTALL...

Страница 4: ...ted to the repair of this product This warranty does not extend to fluorescent lamp starters and tubes THIS LIMITED WARRANTY IS GIVEN IN LIEU OF ALL OTHER WARRANTIES EXPRESSED OR IMPLIED INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE The remedy provided in this warranty is exclusive and is granted in lieu of all other remedies This warranty does not cover incident...

Отзывы: