OBLIGATORY ACCESSORIES:
essential for unit operation:
VEC_GL
Air suction and delivery grille with
Coanda effect adjustable outlets.
White RAL 9010.
CONTROL PANELS
FMT10 FLUSH-MOUNTING CONTROL
PANEL WITH ELECTRONIC THERMOSTAT
Electronic thermostat for fan coils instal-
led in systems with 4 pipes, 2 pipes and
2 pipes with heater, with the possibility
to connect two On-Off valves to shut off
the water feeding the coils. Commands
simplified with only two selectors for
temperature and ventilation control (3
speeds). External air sensor (6m cable
supplied with probe-holder) to be
positioned inside the fan coil. Flush-
mounting (module 503).
See the accessory instructions for further
information.
F M T 2 0 A W F L U S H - M O U N T I N G
CONTROL PANEL WITH ELECTRONIC
THERMOSTAT AND LCD DISPLAY
Electronic thermostat with LCD display
for fan coils installed in systems with
4 pipes, 2 pipes and 2 pipes with
heater, with the possibility to connect
two On-Off valves to shut off the water
feeding the coils. Air temperature sensor
inside the panel. You can connect a
room air temperature sensor (accessory
SWA). You can connect a system water
temperature sensor (accessory SWA).
Flush-mounting (module 503).
KTL P REMOTE CONTROL KIT WITH
THERMOSTAT
Kit with regulating thermostat, consisting
of an infrared remote control, an infrared
receiver, an electronic control card with
air temperature probe, a connection
cable, brackets and everything required
for fixing. KTLP can be applied to a fan
coil installed in a 2-pipe system with
or without a water valve, or a 4-pipe
system with water valves. See the acces-
sory instructions for further information.
PTI MULTIFUNCTION CONTROL
PANEL WITH THERMOSTAT
Electronic control panel with multifun-
ction electronic thermostat for wall-
mounted 2-pipe systems.See the acces-
sory instructions for further information.
PX2 CONTROL PANEL WITH SELECTOR
Control panel with manual command
of the ventilation speed, consisting of
on/off selector and a 3-position selector
for fan speed. Wall mounting. See the
accessory instructions for further infor-
mation.
PXA E CONTROL PANEL WITH MULTI-
FUNCTION ELECTRONIC THERMOSTAT
Multifunction, electronic room ther-
mostat for fan coils in 2-pipe or 4-pipe
systems. Simplified controls with only
two selectors to control temperature and
ventilation, 3 automatic speed,
on-off and automatic summer-winter
switching, according to water tempera-
ture. The minimum water temperature
sensor SW is available as an accessory. It
interrupts the heating function when the
water temperature is below 35°C. Wall-
mounted installation.
See the accessory instructions for further
information.
PXA I CONTROL PANEL WITH MULTI-
FUNCTION ELECTRONIC THERMOSTAT
Multifunction, electronic room ther-
mostat for fan coils in 2-pipe or 4-pipe
systems. Simplified controls with only
two selectors to control temperature and
ventilation, 3 automatic speed,
on-off and automatic summer-winter
switching, according to water tempera-
ture. Equipped with a minimum water
temperature sensor that interrupts the
heating function when the water tem-
perature is below 35°C. Installation on
machine. See the accessory instructions
for further information.
PXA R CONTROL PANEL WITH MULTI-
FUNCTION ELECTRONIC THERMOSTAT
Multifunction, electronic room thermo-
stat for fan coils in 2-pipe systems and
an electric heater. Simplified comman-
ds with only two selectors to control
temperature and ventilation, 3
automatic speed, on/off, activation of the
electric heater when desired, and auto-
matic summer/winter switchover accor-
ding to water temperature. Equipped
with a minimum water temperature sen-
sor that interrupts the heating function
when the water temperature is below
35°C. By suitably adjusting the dip
switches on the card, it can also be used
for 2-pipe or 4-pipe systems without an
electric heater. Wall mounting. See the
accessory instructions for further infor-
mation.
WMT05 CONTROL PANEL WITH
THERMOSTAT
Electronic thermostat for fan coils in
2-pipe systems. The panel is electrical-
ly protected by an internal fuse. Wall-
mounted installation. See the accessory
instructions for further information.
WMT10 CONTROL PANEL WITH
THERMOSTAT
Electromechanical thermostat for fan
coils installed in 4-pipe, 2-pipe and
2-pipe with heater systems, with the pos-
sibility of connecting two On-Off valves
to shut off the water feeding the coils.
The panel is electrically protected by an
internal fuse. Continuous or thermostat-
controlled ventilation. Wall mounting.
ACCESSORIES:
AMP SUPPORTS FOR HANGING
INSTALLATIONS
The installation kit includes the brackets
and nuts and bolts for fixing to the cei-
ling.
B C A U X I L I A R Y T R A Y F O R
COLLECTING CONDENSATE
Made of thermoplastic material, it col-
lects and channels outwards the conden-
sate that is formed during the summer
functioning mode, near the non-insula-
ted plumbing connections.
BV WATER-BASED HEATING COIL
The 1-row heating coil that works with
hot water can be installed in fan coils
in 4-pipe systems, positioned above the
standard coil. The coil can be adjusted
via a control panel able to command the
double valve.
DSC CONDENSATE DISCHARGE DEVICE
Thanks to a pump, this allows you to
discharge the condensate when there
is a difference of levels. It is assembled
outside the device.
PCR COMMAND PROTECTION
In galvanised sheet iron, this is used to
protect the commands and the electric
control board in hanging version models
with electric heater.
RX ELECTRIC HEATER
Protected electric heater complete with
safety thermostat. Available as an acces-
sory for all versions.
SIT 3
Each fan coil fitted with a SIT3 card
becomes a Slave and can be controlled
from a centralised control panel with
an electromechanical selector or with
SIT5. Up to ten fan coils fitted with SIT
3 can be applied to a single centralised
command.
The electronic control panels
and those with valve control must also
be interfaced with a SIT 5.
The electro-
mechanical control panel with just the
speed control can be fitted directly to
the SIT 3 without the SIT 5 interface.
SIT 5
The SIT 5 accessory, a Master interface
card, connects to the electronic con-
trol panels or electromechanical control
panels with command of the valves and/
or electric heaters. The SIT5 interface
card requires that all fan coils connected
to it (up to 10) be fitted with SIT3 Slave
interface cards
.
SW3 MINIMUM WATER TEMPERATU-
RE SENSOR
The SW3 accessory is a sensor that
detects the temperature of the water insi-
de the heating coil and it prevent the
fans from working when the water tem-
perature is less than 39°C. The SW3 sen-
sors are fit for 230V single phase power
supply. The sensor has a 2500mm long
cable.
SWA TEMPERATURE PROBE
SWA outside probe accessory (length L =
6m). The probe detects the temperature
of the ambient air if connected to the
connector (A) of the panel FMT20AW;
the ambient air temperature probe incor-
porated in the panel is automatically
deactivated. It detects the temperature
of the water in the system, for ventilation
consent, if connected to the connector
(W) of the panel FMT20AW. Two SWA
probes can be connected to the panel
FMT20AW simultaneously.
ACCESSORIES
Содержание VEC
Страница 1: ...TECHNICAL MANUAL VEC COANDA EFFECT FAN COIL IVECTY 0906 5074502_01 Replace 5074502_00 0904 ...
Страница 2: ......
Страница 27: ...27 English INSTALLATION H2O H2O AIR H2O A B ...
Страница 28: ...28 English INSTALLING AND REPLACING THE AIR FILTER INSTALLATION Installation A Installation B ...