19
ACCESSORIES
AER485P1
RS-485 interface for supervising systems with
MODBUS protocol.
AERNET:
The device allows the control, the management and
the remote monitoring of a Chiller with a PC,
smartphone or tablet using Cloud connection. AERNET
works as Master while every unit connected is
configured as Slave (max. 6 unit); also, with a simple
click is possible to save a log file with all the connected
unit datas in the personal terminal for post analysis.
PGD1
Allows you to control the chiller at a distance.
MULTICHILLER_EVO
Control, switch-on and switch-off system of the
individual chillers when multiple units are installed in
parallel, always ensuring constant flow rate to the
evaporators.
FL
Flow switch, attention the flow switch and the water filter
must be mounted; failure to do so will void the warranty;
AVX
Spring anti-vibration mounts.
ACCESSORIES MOUNTED IN THE FACTORY :
RIFNRB
Current power factor correction. Connected in parallel
to the motor, it allows a reduction of the input current
(approx. 10%).
GP
Anti-intrusion grid.
XLA
Kit to extend the operating range to 24,8°F of room air
temperature. The condensation temperature is
checked by reducing the fan speed or by partial
switch-off.
COMPATIBILITY with VMF SYSTEM
For further information on system, refer to specific
documentation.
Mod. NRBH
vers.
0800
0900
1000
1100
1200
1400
1600
1800
2000
2200
2400
AER485P1
•
•
•
•
•
•
•
•
•
•
•
AERNET
•
•
•
•
•
•
•
•
•
•
•
PGD1
•
•
•
•
•
•
•
•
•
•
•
MULTICHILLER_EVO
•
•
•
•
•
•
•
•
•
•
•
FL
•
•
•
•
•
•
•
•
•
•
•
AVX
Hydronic kit 00
HA
AVX1000
AVX1004
AVX1004
AVX1004
AVX1004
AVX1006
AVX1006
AVX1010
AVX1010
AVX1016
AVX1016
HE
AVX1004
AVX1006
AVX1006
AVX1006
AVX1006
AVX1010
AVX1013
AVX1024
AVX1024
AVX1033
AVX1033
AVX
Hydronic kit
PA-PB-PC-PD-PE-
PF-PG-PH-DA-DB-
DC
HA
AVX1001
AVX1004
AVX1004
AVX1004
AVX1004
AVX1009
AVX1009
AVX1010
AVX1010
AVX1016
AVX1016
HE
AVX1004
AVX1006
AVX1006
AVX1006
AVX1009
AVX1010
AVX1013
AVX1024
AVX1024
AVX1034
AVX1034
AVX
Hydronic kit
PI-PJ-DD-DE-DF-
DG-DH
HA
AVX1001
AVX1004
AVX1004
AVX1004
AVX1004
AVX1009
AVX1009
AVX1011
AVX1011
AVX1016
AVX1016
HE
AVX1004
AVX1007
AVX1007
AVX1007
AVX1009
AVX1011
AVX1014
AVX1024
AVX1024
AVX1034
AVX1034
AVX
Hydronic kit
DI-DJ
HA
AVX1002
AVX1004
AVX1004
AVX1004
AVX1004
AVX1007
AVX1007
AVX1011
AVX1011
AVX1016
AVX1016
HE
AVX1004
AVX1007
AVX1007
AVX1007
AVX1007
AVX1011
AVX1014
AVX1024
AVX1024
AVX1034
AVX1034
AVX
Hydronic kit
AA-AB-AC-AD-AE-
AF-AG-AH-BA-BB-
BC
HA
AVX1003
AVX1005
AVX1005
AVX1005
AVX1005
AVX1008
AVX1008
AVX1012
AVX1012
AVX1017
AVX1017
HE
AVX1005
AVX1008
AVX1008
AVX1008
AVX1008
AVX1012
AVX1015
AVX1025
AVX1025
AVX1035
AVX1035
AVX
Hydronic kit
AI-AJ-BD-BE-BF-
BG-BH
HA
AVX1003
AVX1005
AVX1005
AVX1005
AVX1005
AVX1008
AVX1008
AVX1012
AVX1012
AVX1017
AVX1017
HE
AVX1005
AVX1008
AVX1008
AVX1008
AVX1008
AVX1012
AVX1015
AVX1025
AVX1025
AVX1035
AVX1035
AVX
Hydronic kit BI-BJ
HA
AVX1003
AVX1005
AVX1005
AVX1005
AVX1005
AVX1008
AVX1008
AVX1012
AVX1012
AVX1017
AVX1017
HE
AVX1005
AVX1008
AVX1008
AVX1008
AVX1008
AVX1012
AVX1015
AVX1025
AVX1025
AVX1035
AVX1035
ACCESSORIES MOUNTED IN THE FACTORY
RIFNRB
(1)
•
•
•
•
•
•
•
•
•
•
•
GP
(1)
•
•
•
•
•
•
•
•
•
•
•
XLA
(1)(2)
HA
-
-
-
-
-
•
•
•
•
•
•
HE
-
•
•
•
•
•
•
•
•
•
•
(1) Accessories to be defined for coupling, we recoinend contacting the manufacturer.
(2) To operate from 14°F to -4°F of external air, it is mandatory to use the XLA accessory coupled only with inverter fans "J".