WEIGHT DISTRIBUTION

Upper view

1 3 5 7 9 11 13 15 17 19 21

Evaporator side

Compressors side

Compressors side

x

y

2 4 6 8 10 12 14 16 18 20 22

Model Size Versions WEIGHT 

Empty

BARYCENTRE WEIGHT 

Working

BARYCENTRE

Weight distribution % on the support  (Based on the weight in operation)

XG1 YG1

XG1 YG1

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

lbs

[in] [in]

lbs

[in] [in]

%

%

%

%

%

%

%

%

%

%

%

%

%

%

%

%

%

%

%

%

%

%

NRB 0800 HA/HE

6790

80

49

6845

80

49

15,4 20,2

0

0

27,9 36,6

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

NRB 0900 HA/HE

8444

100

47

8499

100

47

12,0 14,2 13,2 15,7

0

0

20,5 24,3

-

-

-

-

-

-

-

-

-

-

-

-

-

-

NRB 1000 HA/HE

8929

99

48

9006

99

48

12,0 14,8 12,9 15,9

0

0

19,9 24,6

-

-

-

-

-

-

-

-

-

-

-

-

-

-

NRB 1100 HA/HE

8995

100

48

9072

99

48

11,8 14,8 12,8 16,0

0

0

19,8 24,8

-

-

-

-

-

-

-

-

-

-

-

-

-

-

NRB 1200 HA/HE

9237

99

48

9348

98

48

12,0 14,8 13,1 16,3

0

0

19,6 24,2

-

-

-

-

-

-

-

-

-

-

-

-

-

-

NRB 1400 HA/HE

10538 119

48

10648

119

47

10,4 12,7 10,8 13,1

0

0

14,3 17,5 9,6 11,7

-

-

-

-

-

-

-

-

-

-

-

-

NRB 1600 HA/HE

11707 144

47

11839

143

47

7,3

8,7 11,5 13,8

0

0

14,2 17,0

0

0

12,5 15,0

-

-

-

-

-

-

-

-

-

-

NRB 1800 HA/HE

13184 161

47

13316

160

47

8,5

9,9

6,5

7,6

8,0

9,4

0

0

13,2 15,5

0

0

9,9 11,6

-

-

-

-

-

-

-

-

NRB 2000 HA/HE

13316 160

47

13481

159

46

8,4

9,8

6,8

7,9

7,9

9,3

0

0

13,1 15,3

0

0

9,9 11,5

-

-

-

-

-

-

-

-

NRB 2200 HA/HE

15366 193

47

15532

192

46

5,1

5,9

2,9

3,4 12,9 14,9

0

0

9,6 11,1

0

0

10,6 12,3 5,2

6,1

-

-

-

-

-

-

NRB 2400 HA/HE

15807 194

47

16061

193

47

4,8

5,8

3,2

3,8 12,1 14,6

0

0

9,3 11,3

0

0

11,1 13,4 4,8

5,8

-

-

-

-

-

-

Содержание NRB 0800

Страница 1: ...BARCODE EN Installation and Maintenance Manual TRANSLATION FROM ORIGINAL 21 01 4138476_03 OUTDOOR INSTALLATION MICROCHANNEL COIL NIGHT MODE NRB H 0800 2400 60Hz...

Страница 2: ......

Страница 3: ...st grade materials and with cutting edge technology The quality level is being constantly monitored so AERMEC products are synonymous with Safety Quality and Reliability The data may undergo modificat...

Страница 4: ...tronic Equipment WEEE please return the device using appropriate collection systems or contact the retailer where the product was purchased Please contact your local authority for further details Ille...

Страница 5: ...NECTIONS 15 ELECTRIC POWER CONNECTION TO THE ELECTRICAL MAINS 16 ELECTRICAL DATA 208V 3 60HZ FAN J 17 ELECTRICAL DATA 230V 3 60HZ FAN J 17 ELECTRICAL DATA 460V 3 60HZ FAN J 17 ELECTRICAL DATA 460V 3 6...

Страница 6: ...ecessary repairs The installation must comply with the requirements of EN378 3 and the local current regulations In particular indoor installation must ensure adequate ventilation and provide refriger...

Страница 7: ...tures with ethylene glycol propylene in a maximum concentration of 30 The machine must only be employed for the use for which it was made any other use can be dangerous and void the warranty PreVentiO...

Страница 8: ...etails of the problem to the shipping company within 48 working hours from delivery lifting Before lifting the unit place protections between the belts or ropes and chains and the framework to prevent...

Страница 9: ...heck that the contact surfaces of the anti vibration supports are levelled to the base If necessary use spacers or level the base but in any case make sure that the anti vibration supports rest flat o...

Страница 10: ...AA BH NRB n n in in in 0800 HA HE 3 6 97 87 156 0900 HA HE 4 8 97 87 203 1000 HA HE 4 8 97 87 203 1100 HA HE 4 8 97 87 203 1200 HA HE 4 8 97 87 203 1400 HA HE 5 10 97 87 250 1600 HA HE 6 12 97 87 297...

Страница 11: ...ectric power board Unit Vers V block Fans Panel type A B C D E NRB H n n in in in in in 800 HA HE 3 6 1 39 43 39 32 118 900 HA HE 4 8 1 39 43 39 32 118 1000 HA HE 4 8 1 39 43 39 32 118 1100 HA HE 4 8...

Страница 12: ...8 12 0 14 8 12 9 15 9 0 0 19 9 24 6 NRB 1100 HA HE 8995 100 48 9072 99 48 11 8 14 8 12 8 16 0 0 0 19 8 24 8 NRB 1200 HA HE 9237 99 48 9348 98 48 12 0 14 8 13 1 16 3 0 0 19 6 24 2 NRB 1400 HA HE 10538...

Страница 13: ...in the highest points of the circuit and also provide discharge fittings in the lowest points to allow emptying the entire circuit To maintain the pressure in the circuits you must install an expansio...

Страница 14: ...IL RISARCIMENTO DEI DANNI NE UTILIZZARE IL CONTENUTO O RENDERLO COMUNQUE NOTO A TERZI SENZA LA NOSTRA NON E PERMESSO CONSEGNARE A TERZI O RIPRODURRE QUESTO DOCUMENTO SOST DA SOST IL APPROV CONTR DISE...

Страница 15: ...am fig 1 The use of an omnipolar magnet circuit breaker switch in compliance with the current Standards contact opening at least 0 12 in with suitable cut off power and differential protection on the...

Страница 16: ...N TO THE ELECTRICAL MAINS 2 B F 3 31 03 2017 4 RIEPILOGOMORSETTI 5 E 1 31 03 2017 1 2 6 5 6 C D NOME FILE TIPICO SUBITI E FATTA RISERVA DI TUTTI I DIRITTI DERIVANTI DA BREVETTI O MODELLI AUTORIZZAZION...

Страница 17: ...J 460V 3 60Hz fan J Units LRA MCA MOP Recommended fuse Phases Mod Comp Fan NRB Vers n n A A A n n 0800 HA HE 4 6 291 129 156 150 3 0900 HA HE 4 8 341 139 169 150 3 1000 HA HE 4 8 357 155 185 175 3 11...

Страница 18: ...00 HA HE 4 14 575 254 306 250 3 2200 HA HE 5 16 600 298 350 300 3 2400 HA HE 6 16 506 348 398 350 3 575V 3 60Hz fan Units LRA MCA MOP Recommended fuse Phases Mod Comp Fan NRB Vers n n A A A n n 0800 H...

Страница 19: ...VX1016 AVX1016 HE AVX1004 AVX1006 AVX1006 AVX1006 AVX1006 AVX1010 AVX1013 AVX1024 AVX1024 AVX1033 AVX1033 AVX Hydronic kit PA PB PC PD PE PF PG PH DA DB DC HA AVX1001 AVX1004 AVX1004 AVX1004 AVX1004 A...

Страница 20: ...ure drop tables present in this manual Check the correct functioning of the flow meters if installed Closing the cut off valve at the output of the heat exchanger the unit control panel must show the...

Страница 21: ...tivation before accessing them Isolate the unit from the mains by means of the external isolator provided for the insertion of padlocks up to 3 for blocking in open position Place a sign reading Do no...

Страница 22: ...placed after draining the refrigerant gas contained in the circuit During venting protect yourself against any leakage of fluids at dan gerous temperatures and or pressures Always use appropriate equi...

Страница 23: ...e machine panel where the control panel is located remaining distant and not exposed to the under pressure parts of the cooling circuit CLEANING COIL MICRO CHANNEL Keep surfaces clean battery mirco ch...

Страница 24: ...particular attention to under pres sure containers In this case replace them of intervene with specific products General cleaning of the unit Bleed the hydraulic circuit and the heat exchangers the si...

Страница 25: ...ctioning of the thermostatic valve Check the charge of refrigerant gas 1 Check the proper functioning of the solenoid valves MAINTENANCE LIST OF THE RECOMMENDED PERIODIC INTERVENTIONS DECOMMISSIONING...

Страница 26: ......

Страница 27: ......

Страница 28: ...qua VR Italia Tel 39 0442 633111 Fax 39 0442 93577 marketing aermec com www aermec com Aermec reserves the right to make all modification deemed necessary for improving the product at any time with an...

Отзывы: