Page 12 of 29
We recommend to keep the packaging to ensure safe shipment of
the air dehumidifier in case of any warranty claim.
5.
Use the carrying handles to transport the air dehumidifier to the place of
installation.
Installation
Proceed as follows to install and transport the air dehumidifier:
1.
Install the air dehumidifier in a place in conformity with the operating
conditions on a flat surface (see below).
2.
Ensure that the condensate can always be reliably collected or discharged.
Operating conditions
Air dehumidifiers are intended for mobile or stationary use in closed rooms, on
building sites, in water works, indoor swimming pools, garages and storage
rooms.
The air dehumidifiers works without problems in the temperature range from +1
deg. C to +34 deg. C and in the humidity range from 35 to 99 percent relative
humidity.
In case of lower or higher temperatures, the unit switches off automatically.
Using the appliance in rooms with lower temperatures is inefficient and can
result in icing.
Storage of the air dehumidifier at impermissible temperature conditions can
result in damage / problems in case of immediate switching-on.
In case of storage below 0 °C the device must first be allowed to acclimatize to
the room temperature before use. Therefore allow the air dehumidifier to adjust
to the temperature before switching it on.
The suitable location for the air dehumidifier features:
230 V / 50 Hz power outlet
Flat ground
Free space of 1 meter minimum in front of the air outlet lamellae and air
filter, better more!