Instruction Manual
1. GENERAL
2. TRANSMITTER AND RECEIVER TERMINAL CONNECTIONS
3. TRANSMITTER - REGULAR CONFIGURATION FOR OSE
1 2 3
4 5 6
INPUT 1
COM 1
INHIBITOR
COM 2
INPUT 2
VCC
1 2 3 4 5 6 7 8 9 10 11 12
VCC1
OUTPUT 1
VCC2
OUTPUT 2
TEST
RELAY 1
TEST RELAY 2 /
INHIBITOR
+/
~
-
/
~
12/24V
AC/DC
TRANSMITTER
RECEIVER
1 2 3
4 5 6
INPUT 1
COM 1
Inhibitor
COM 2
INPUT 2
VCC
GND / 0V
OUTPUT SIGNAL
Optical Low Power Safety Edge
WHITE
BROWN
GREEN
5 VDC
TRANSMITTER
EN
1 - 8
See point 11.1 for other
transmitter connections.
- Two channel wireless system communication for either optical, resistive or mechanical safety edges.
Translation of the original instructions
1.1 SAFETY INSTRUCTIONS
- Reaction time < 60ms.
(according TÜV test report AV86368T
Certificate nº M6A 0908000001 Rev. 01
)
- A Relay test should be done before any operation in order to fulfill EN13849-1-2015 Cat2 PL-C.
ACTIVATED BY
TRANSMITTER
INPUT 1
ACTIVATED BY
TRANSMITTER
INPUT 2
IP55
2 yrs
Battery
100m 2 Ch
Output
7Tx
RoHS
1
2
3
4
ON
5
Optical sensor power
supply from receiver (ON)
Optical sensor power
supply from receiver (OFF)
Sleeping mode
in receiver (ON)
Receiver options configuration
for Optical Safety Edge
1
2
3
ON
+
SAFETY
(KIT WIRELESSBAND 2 OSE)
SAFETY
Safe configuration
Fullfil EN13849-1 Cat 2 PL-C
Non-Safe configuration
x
KIT WIRELESSBAND 2 OSE
18/11/20