TECHNICALLY REQUIRED MINIMUM DISTANCES
To allow regular and extraordinary maintenance work on the unit, minimum distances
of
1 m
from walls, railings, other appliances or similar obstacles must be provided on
all sides of the unit.
If the unit is inadequately fixed, it may come loose and start moving. There is a danger of per-
sonal injury or damage to property.
Secure the device properly and in accordance with the requirements of the installation site. The fasteners
must be distributed evenly across all system feet. Both through holes in the feet must be used for screw
connections. The type of fastener must be determined independently by the installer. Check whether drilling
into the ceiling is permitted.
The fastening is planned and completed on site. In particular, when selecting the fasteners and weights for
any loading, the expected weather conditions and other project-specific influencing factors must be taken
into account. The dimensioning of the fastening must be carried out in accordance with DIN EN 1991-1-4.
CONNECTIONS TO BE PROVIDED BY THE CUSTOMER
The following cables or connections must be available for mounting the device.
Medium
Connection
Number/connection type
Wa
te
r
Supply line
1*
Return line
1*
Condensate line
1* (e.g. 16 mm)
Power
AWN on main switch
L/N/PE 230 volt*
Trace heating for heating water pipes
According to local conditions*
Trace heating for condensate line
According to local conditions*
Protective equipotential bonding
1*
Sig
na
l
Heat pump release**
2* (e.g. 0.75 mm²)
Buffer sensor
2* (e.g. 0.75 mm², shielded)
Fault message
2* (e.g. 0.75 mm²)
Smart Grid
(optional when using PV power)
2* (e.g. 0.75 mm²)
EVU release
(optional for heat flow rate)
2* (e.g. 0.75 mm²)
KW inlet flow switch (optional)
2* (e.g. 0.75 mm²)
Heating circuit return sensor (optional)
2* (e.g. 0.75 mm², shielded)
CMI module
(optional when using remote mainte-
nance)
5* (e.g. 0.75 mm²)
* All pipe cross-sections must be designed independently, professionally and in accordance with standards
in accordance with local conditions.
** The heat pump can be switched on and off via the EVU release (input 1). The exhaust fan is intended for
continuous operation. A corresponding release line is therefore not provided for the ventilation components.