11
WHS RANGE
Ceiling High Volume Low Speed Fan (HVLS)
INDEX
1.
GENERAL INFORMATION
11
2.
PRECUTIONS
11
3.
TYPE
11
4.
MAIN
FEATURES
12
5.
DATA
12
6.
DIMENSIONS
AND
CLEARANCES
12
7.
COMPONENTS
12
8.
INSTALLATION
13
9.
WIRING
DIAGRAM
16
9.1
CTRL-A
(accessory
on
request)
16
9.2
CTRL-HS
(accessory
on
request)
16
9.3 CONTROL WITH EXTERNAL POTENTIOMETER (not supplied)
17
10.
CLEANING
17
11.
TROUBLESHOOTING
17
11.1
Connection
parameters
17
11.2 Modbus registers - Input register
17
11.3 Alarm codes / led status / troubleshooting
18
12. DECLARATION OF CONFORMITY AND INCORPORATION
19
1. GENERAL INFORMATION
Carefully read the instructions contained in this manual.
This Specific Manual MUST be read in conjunction with the “Installation, Operation and Maintance General Manual”.
Note: store the manual for future reference. We reserve the right to improve and make changes to the manual, products and
accessories without any obligation to update previous productions and manuals.
2. PRECAUTIONS
In addition to the precautions indicated in the “Installation, Operation and Maintenance General Manual” special attention should
be paid to the following warning notes:
- fixing: check/inspect and eventually retighten all the fixing annually.
- windy conditions: fans should not operate in case of strong wind (6m/s) and should not be installed in places where it is
frequently windy.
- weight: it is recommended that the building structure is capable to bear approx. twice the weight of the fan as well as a
torque of at least 350Nm. A professional structural engineer should perform an evaluation before installing the fan.
- key safety features: make sure that all the supplied key safety features are used to install the fan to provide a comprehensive
protection of people, animals, equipments and property.
The installer and the building owner are responsible to ensure the safety of the fan mounting system and that the fan installation
is correct, in compliance with any national and local regulations.
Table 1
Use the values shown in the table to tighten all the screws.
Size
Nm
M6
9,5
M8
23
M10
46
M12
79
M14
127
M16
198
RECOMMENDED BOLT TORQUE FOR COARSE THREADED METRIC STEEL BOLTS TE-TCEI
GRADE 8.8
3. TYPE
Ceiling fans with EC brushless motor designed for industrial, civil and zootechnical applications, where high performance with
low rotation speed are required.
EN