Aeon Labs Home Energy Meter 

(Z-Wave Home Energy Meter) 

 

  

Introduction: 

The Aeon Labs Home Energy Meter is energy meter for the 

entire  home.    It  can  wirelessly  report  immediate  wattage 

and kWh usage of the AC mains to a Z-Wave gateway.   

By  taking  advantage  of  the  Z-Wave  mesh  network, 

commands  can  be  routed  to  their  destination  via 

intermediary  “listening”  Z-Wave  products.    Products  that 

are  Z-Wave  certified  can  be  used  and  communicate  with 

other Z-Wave certified devices. 

Z-Wave Network Instructions: 

The  Aeon  Labs  Home  Energy  Meter  must  be  paired 

(included)  into  a  Z-Wave  network  before  it  can  receive  Z-

Wave  commands  to  report  its  energy  usage.    The  home 

energy  meter  can  only  communicate  to  devices  within  it’s 

own z-wave network. 

Note

If the Home Energy Meter is not currently paired into 

a Z-Wave network, the LED on the Home Energy Meter will 

blink after pressing the button located near the batteries. 

 

Adding/Including/Pairing the Home Energy Meter 

into a Z-Wave Network 

1.

 

Press the button on the Aeon Labs Z-Stick to begin the 

Z-Wave inclusion process. 

 

OR 

 

Press  the  button  labeled  “Include”  on  the  Aeon  Labs 

Minimote to begin the Z-Wave inclusion process. 

 

Note

:  To  include  the  Aeon  Labs  Home  Energy  Meter 

with  other  controllers,  please  consult  the  operation 

manual  for  these  controllers  on  how  to  include  Z-

Wave  products  into  an  existing  network.    For 

instructions  on  select  partner  gateways,  visit 

www.aeon-labs.com/support. 

2.

 

After  placing  4  AA  batteries  into  the  Home  Energy 

Meter, press the button located near the batteries . 

 

Troubleshooting

: If the Aeon Labs Home Energy Meter was 

not successfully included into any Z-Wave network, the LED 

will blink after pressing the button near the batteries.  If the 

Aeon Labs Home Energy Meter was successfully included to 

a Z-Wave network, the LED will be lit solid after pressing the 

button. 

 

 

 

Removing/Excluding/Resetting the Home Energy 

Meter from your Z-Wave Network 

1.

 

Hold the button on the Aeon Labs Z-Stick to begin the 

Z-Wave removal process. 

 

OR 

 

Press the button labeled  “Remove”  on  the  Aeon Labs 

Minimote Stick to begin the Z-Wave removal process. 

 

Note

:  To  include  the  Aeon  Labs  Home  Energy  Meter 

with  other  controllers,  please  consult  the  operation 

manual  for  these  controllers  on  how  to  include  Z-

Wave  products  into  an  existing  network.    For 

instructions  on  select  partner  gateways,  visit 

www.aeon-labs.com/support. 

 

2.

 

After  placing  4  AA  batteries  into  the  Home  Energy 

Meter, press the button located near the batteries . 

 

Troubleshooting

: If the Aeon Labs Home Energy Meter was 

removed from the Z-Wave network, the LED will blink after 

pressing  the  button  near  the  batteries.    If  the  Aeon  Labs 

Home  Energy  Meter  was  not  successfully  removed  from  a 

Z-Wave network, the LED will be lit solid after pressing the 

button. 

 

 

 

 

Power by an USB/AC Adapter 

 

While  the  Aeon  Labs  Home  Energy  Meter  can  operate  for 

nearly a year  on  batteries,  it can  also  be powered  through 

it’s  USB  port.    While  powered  by  the  USB  port,  the  Home 

Energy  Meter  can  track  kWh  energy  usage  and  report 

wattage every few seconds. 

 

AC Mains Installation 

IMPORTANT:

  It  is  recommened  that  a  licensed  electrician 

assist  with  the  installation  as  you  must  open  the  main 

circuit box (usually located outside of your house). 

 

After  opening  the  main  circuit  box  panel,  clip  each  of  the 

clamps  of  the  Aeon  Labs  Home  Energy  Meter  around  the 

two incoming wires that connect to the main circuit breaker 

from the main wire going into the box. 

If you have purchased the optional Home Energy Meter AC 

Adapter,  you  may  insert  one  of  the  AC  adapters  exposed 

wires  into  one  of  the  neutral  bus  terminals  and  the  other 

exposed wire into the live terminals coming from the  main 

circuit breaker. 

 

Note

Some  AC  Mains  boxes  are  made  of  metal  and  may 

reduce  the  radio  communication  power  from  the  Home 

Energy Meter to other Z-Wave devices within the house.  To 

improve  radio  performance,  the  Home  Energy  Meter  may 

be placed outside of the main circuit box.  The Home Energy 

Meter is IP43 weatherized to be resistant to rain and snow 

when  placed  vertically  with  the  wires  protruding  from  the 

bottom of the unit. 

- 1 -                                                                                                                  - 2 -                                                                                                                       - 3 -                                                                                                                     - 4 - 