Simple Logger® Temperature Module Model L605 

 

1.2 

Definition of Measurement Categories

Cat. IV:  

For measurements performed at the primary electrical supply

 

(<1000V) such as on primary overcurrent protection devices, 

ripple control units, or meters.

Cat. II: 

For  measurements  performed  on  circuits  directly  connected  to 

the electrical distribution system. Examples are measurements

 

on household appliances or portable tools.

 

Cat. III:

  For  measurements  performed  in  the  building  installation  at 

the  distribution  level  such  as  on  hardwired  equipment  in  fixed 

installation and circuit breakers.

1.3 

Receiving Your Shipment

Upon receiving your shipment, make sure that the contents are consistent 

with the packing list. Notify your distributor of any missing items. If the equip

-

ment appears to be damaged, file a claim immediately with the carrier and 

notify your distributor at once, giving a detailed description of any damage. 

Save the damaged packing container to substantiate your claim.

1.4 

Ordering Information

Simple Logger

®

 Model L605

 .............................................

Cat. #2114.17

(Temperature – Internal/External Thermistor)

Includes software (CD-ROM), 6 ft DB-9 RS-232 serial cable, 9V Alkaline battery and user 

manual.

1.4.1  Accessories and Replacement Parts

Thermistor Probe with Epoxy bead, 6 ft

 ..............................

Cat. #2114.19

Thermistor Probe with 4" Stainless Steel Sheath, 6 ft .........

Cat. #2114.20

Order Accessories and Replacement Parts Directly Online

Check our Storefront at 

www.aemc.com/store

 for availability

Содержание L605

Страница 1: ...SIMPLE LOGGER TEMPERATURE MODULE L605 E N G L I S H User Manual...

Страница 2: ...he case Please record this number and purchase date for your records SIMPLE LOGGER MODEL L605 CATALOG 2114 17 SERIAL _ _______________________________________________ PURCHASE DATE ___________________...

Страница 3: ...ctrical Specifications 6 3 2 Mechanical Specifications 7 3 3 Environmental Specifications 7 3 4 Safety Specifications 7 4 OPERATION 8 4 1 Software Installation 8 4 2 Recording Data 9 4 3 Using the Sof...

Страница 4: ...nstrument while connected to any circuit or input ALWAYS inspect the instrument and lead prior to use Replace any defective parts immediately NEVER use the Model L605 on electrical conductors rated ab...

Страница 5: ...ment appears to be damaged file a claim immediately with the carrier and notify your distributor at once giving a detailed description of any damage Save the damaged packing container to substantiate...

Страница 6: ...gger Single Blink STAND BY mode Double Blink RECORD mode Continuously On OVERLOAD condition No Blinks OFF mode 1 2 3 4 1 Start Stop Button 2 Inline Connector for External Sensor 3 LED Indicator 4 RS 2...

Страница 7: ...ht side of the logger has a female 9 pin D shell serial connector used for data transmission from the data logger to your computer 2 3 Mounting Your Simple Logger is equipped with mounting holes in th...

Страница 8: ...Impedance Thermistor type 10k 77 F 25 C Resolution 8 Bit Change in Temperature vs Range 9 00 8 00 7 00 6 00 5 00 4 00 3 00 2 00 1 00 0 00 1 00 2 00 2 5 1 5 5 5 1 5 2 5 3 5 4 5 5 5 6 5 7 5 8 5 9 5 Tem...

Страница 9: ...nnector 1200 Bps 3 2 Mechanical Specifications Size 2 7 8 x 2 5 16 x 1 5 8 73 x 59 x 41mm Weight with battery 5 oz 140g Mounting Base plate mounting holes or Velcro pads Case Material Polystyrene UL V...

Страница 10: ...each stored file One 9 pin serial port one parallel port for printer support CD ROM drive 1 Insert the Simple Logger CD into your CD ROM drive If auto run is enabled the Setup program will start autom...

Страница 11: ...n of the Set up window then select Simple Logger Version 6 xx in the Options section 4 Click the Install button and follow the on screen prompts to install the software 4 2 Recording Data If the tempe...

Страница 12: ...software automati cally detects the baud rate the logger will communicate with the computer ID number of the logger and number of points recorded displayed 4 3 1 The Function Command The Function com...

Страница 13: ...ase plate then take off the base plate 3 Locate the two wire red black battery connector and attach the 9V battery to it Make sure that you observe polarity by lining up the battery posts to the prope...

Страница 14: ...ble click on the desired file to open the Text Import Wizard 5 Review the selections in the first wizard screen and make sure that the following choices are selected Original Data Type Delimited Start...

Страница 15: ...Click on column B at the top of the column to select the data then click on Insert from the main menu and select Columns from the drop down menu 2 Next click on column A at the top of the column to s...

Страница 16: ...Time option from the category list on the left Select the time format you desire and click on OK to format the column FigureA 2 shows a typical spreadsheet with date time and value displayed It may be...

Страница 17: ...T Includes calibration certificate plus recorded calibration data Ship To Chauvin Arnoux Inc d b a AEMC Instruments 15 Faraday Drive Dover NH 03820 USA Phone 800 945 2362 Ext 360 603 749 6434 Ext 360...

Страница 18: ...eriod you may return the in strument to us for repair provided we have your warranty registration information on file or a proof of purchase AEMC Instruments will at its option repair or replace the f...

Страница 19: ......

Страница 20: ...08 18 99 MAN 100213 v10 Chauvin Arnoux Inc d b a AEMC Instruments 15 Faraday Drive Dover NH 03820 USA Phone 603 749 6434 Fax 603 742 2346 www aemc com...

Отзывы: